EG_GenTrack23e_997_UG_005_UK
Page 14 / 39
Descriptions and non-contractual illustrations in this document are given as an indication only.
ERCO&GENER reserves the right to make any modifications.
3.2 External connections
3.2.1 GenTrack 23e connections
WARNING
: The GenTrack 23e can be powered to charge their battery only through their charger
base.
3.2.2 Charger connections
3.2.2.1 Micro Fit connector
The Micro Fit 4-point connector is used to connect the external DC supply, used to charge the GenTrack.
WARNING
: The power voltage must be between
5 VDC
mini
and 15 VDC maxi.
3.2.2.2 USB connector
The USB connector (type B) is used for the connection of the USB 2.0 link (Full Speed compatible). The USB
port is used to program and to recover the data stored in the Gentrack23e.
When there is no external supply connected on the Micro-Fit 4-point connector, the USB supply can be used
for a slow charge of the unit (the time of charge depends on the voltage available on the USB output)
Pin N°
Signal
1 +VDC
2 GND
3 NC
4 NC
Pin N°
Name
1
5V (VBUS) 500mA max.
2 Data
(D-)
3 Data
(D+)
4 Ground
(GND)