5.8 Main AT commands (HAYES) 

 

The table below shows at a quick glance the main AT commands useful for the control of the modem. 

For further information concerning the complete command set see the Wavecom "AT Commands Interface 

Guide" and the ERCO&GENER "Commands List”. 

 

Table : Main AT commands used with the modem. 

Description 

AT Command 

Response 

Interpretation 

Enter the PIN code 

AT+CPIN=xxxx 

OK 

PIN code accepted 

(xxxx = PIN code) 

+CME ERROR: 16 

PIN code incorrect (1*) 

 

+CME ERROR: 3 

PIN code already entered (1*) 

Verification of GSM 
network registration 

AT+CREG? 

+CREG: 0,0 

The modem is not recognised by the 
network. 

 

+CREG: 0,2 

The modem is searching for a 
network operator. 

 

+CREG: 0,1 

The modem is GSM attached to a 
local operator. 

 

+CREG: 0,5 

The modem is GSM attached to an 
operator in roaming mode. 

Reception of an 
incoming call (2*) 

ATA 

OK 

Reply to the call 

Make a voice call 

ATD<telephone 
number>; 

OK 

Communication established 

(IMPORTANT: the 

;

 at 

the end of the sequence 
specifies a voice call) 

+CME ERROR: 11 

PIN code not entered 

+CME ERROR: 3 

The credit has run out or the 
communication has already been 
established. 

Make an emergency 
call (112) 

ATD112; 

OK 

Communication established 

Lost communication   

NO CARRIER 

 

Hang-up ATH 

OK 

 

 

(1*) The command 

AT+CMEE=1 

 allows the display of extended error codes. This command may be saved 

with the command 

AT&W

.  

The command 

AT+WIND=63 

allows the display of the change of status of the SIM card (present, 

ready…) and to check divers modem states (modem ready after RESET…). This command may be 

saved with the command 

AT&W

(2*) The command 

AT+CRC=1 

will in the case of an incoming call, display more detailed ring information 

indicating the type of call - voice, data or fax. This command may be saved with the command 

AT&W

Examples : 

For VOICE : +CRING: VOICE  

For DATA :  +CRING: REL ASYNC 

For FAX :  +CRING: FAX 

 

Summary of Contents for GenPro 20e

Page 1: ...vision 008 Date 24 06 2011 S A ERCO GENER ZI de St Lambert des Lev es BP 30163 F 49412 SAUMUR Cedex T l 33 0 2 41 83 13 00 Fax 33 0 2 41 67 19 20 www ercogener com infos ercogener com SA CAPITAL 20087...

Page 2: ...rective page 50 F LE BRETON 06 03 07 003 Removed Memory Flash 16 Mbits page 7 Added warning SIM during the Firmware update OS page 26 Modified Buzzer page 41 F LE BRETON 19 03 07 004 Modified idle mod...

Page 3: ...ND SERVICES 17 5 USING THE MODEM 18 5 1 Starting with the modem 18 5 1 1 Mounting the modem 18 5 1 2 Installation of the modem 18 5 1 3 Communication with the modem 19 5 1 4 Re initialisation of the m...

Page 4: ...8 2 2 1 Microphone and Loud speaker 40 8 2 2 2 Buzzer option 41 8 2 3 SIM Interface 41 8 2 4 General purpose inputs output 42 8 2 4 1 Inputs 42 8 2 4 2 Output 43 8 2 5 RESET Signal 43 8 2 6 GSM DCS 4...

Page 5: ...mentary applications The GenPro modem provides the TCP IP protocols as well as 3 inputs and 1 output allowing the immediate development of onboard high value added telematic solutions The GenPro provi...

Page 6: ...of their respective holders Use of certain products or services described in this document may require subscription or a paying subscription The availability of certain products or services described...

Page 7: ...X X DATA Features GPRS Class 10 up to 4Rx 2Tx X X Supports PBCCH Coding schemes CS1 CS4 X X TCP IP Library PPPRFC TCP Socket UDP Socket SMTP POP3 FTP X X Asynchronous data circuit transparent and non...

Page 8: ...l relative to an Isotropic radiator dBm Decibel relative to one milliwatt DC Direct Current DCD Data Carrier Detect DCE Data Communication Equipment DCS Digital Cellular System DSR Data Set Ready DTE...

Page 9: ...puter PCL Power Control Level PDP Packet Data Protocol PIN Personal Identity Number PLMN Public Land Mobile Network PUK Personal Unblocking Key RF Radio Frequency RFI Radio Frequency Interference RI R...

Page 10: ...ons 2 Packing 2 1 Contents The GenPro is supplied with GenPro packing case GenPro modem 2 fixing brackets Instructions Sheet 4 wire cable Red Black Orange Green with in line fuse depending on GenPro 2...

Page 11: ...ched to the top of the packing case It contains The ERCO GENER logo The product reference GenPro xxe CE mark Hardware WatchDog mark The IMEI 15 digit bar code Identification label dimensions Height 37...

Page 12: ...ht to make any modifications 3 General Presentation 3 1 Physical Description Description of the GenPro 2xe modem Connector Micro Fit 4 pins M Connector Micro Fit 2 pins M only on GenPro 24e Connector...

Page 13: ...rs 4 pin Micro FIT female connector This connector allows the connection of an external DC supply and provides one general purpose input and one general purpose output Pin N Signal 1 VDC 2 GND 3 INPUT...

Page 14: ...nal detection Buzzer 109 DS DCD O 2 Data transmission 103 ED TXD I 3 Boot BOOT I 4 Microphone MIC2P I 5 Microphone MIC2N I 6 Data reception 104 RD RXD O 7 Data Set Ready 107 PDP DSR O 8 Data Terminal...

Page 15: ...ces table 3 2 2 1 4 wire micro FIT supply cable This cable provides power to the modem Component Characteristics 4 pin Micro FIT connector Type MOLEX Cable Length 1 5m Wire Tinned copper 24 x 0 2 mm S...

Page 16: ...ent are given as an indication only ERCO GENER reserves the right to make any modifications 3 2 2 3 2 wire micro FIT inputs cable This cable provides access to two general purpose inputs Component Cha...

Page 17: ...eneral purpose inputs and 1 output The characteristics of the different GenPro are shown in the Product Differences table Options and accessories available for the modem GenPro modem are shown in the...

Page 18: ...o perform the following operations with the modem turned off Remove the SIM card cover on the rear side Carefully insert the SIM card into its holder Verify that the SIM card is positioned correctly C...

Page 19: ...ommunication has been established and verified these commands are explained in detail later in the document AT CGSN the modem should reply with a 15 digit number beginning with 35873000xxxxxxx AT CPIN...

Page 20: ...eaker outside the cabin The circuit breaker is necessary for security reasons For example if a fire breaks out in the lorry s electric box the driver may cut the power source to avoid further danger a...

Page 21: ...ground of the battery will be connected together via the modem as shown in the diagram below Example of a forbidden electrical connexion risk of damage to the modem The diagram above shows an electric...

Page 22: ...e LED flashing Once a second The modem is powered and currently in communication Voice Data or Fax OFF LED off The modem is not powered or is in the RESET phase 5 4 AT commands Echo deactivated If no...

Page 23: ...s Using a communication application enter the command AT CSQ The response is in the following format CSQ rssi ber where rssi indicates the reception level ber receive bit error rate Verify the value r...

Page 24: ...e that a valid SIM card is present in the SIM card reader in the modem 2 Using a communications application enter the following AT commands a AT CPIN xxxx Enter the PIN code The user has only 3 attemp...

Page 25: ...ocal operator CREG 0 5 The modem is GSM attached to an operator in roaming mode Reception of an incoming call 2 ATA OK Reply to the call Make a voice call ATD telephone number OK Communication establi...

Page 26: ...AT CFUN 0 identical functioning The modem will return OK and is no longer registered on the network The radio module is put into standby and the power may then be removed Note There is no particular a...

Page 27: ...n chapter 3 2 1 3 15 pin Sub HD female connector Cable the serial cable according to the table in chapter 3 2 1 3 15 pin Sub HD female connector Returns nothing or random characters Is the communicati...

Page 28: ...quality Is the modem registered on the network Verify network registration see chapter 5 7 Verifying modem registration on the GSM network Is the antenna correctly connected Check the GSM antenna ins...

Page 29: ...nding 19 User alerting no answer 21 Call rejected 22 Number changed 31 Normal unspecified 50 Requested facility not subscribed Check your subscription data subscription available 68 ACM equal to or gr...

Page 30: ..._UG_008_UK Page 30 51 Descriptions and non contractual illustrations in this document are given as an indication only ERCO GENER reserves the right to make any modifications 7 Functional Description 7...

Page 31: ...er source of between 5 5V and 32V The modem s various internal DC voltages are provided by an internal DC DC converter The correct functioning of the modem cannot be guaranteed if the input voltage V...

Page 32: ...ees Input output EMI RFI protection Signal smoothing The following signals are available TX data CT103 TX RX data CT104 RX Request To Send CT105 RTS Clear To Send CT106 CTS Data Terminal Ready CT108 2...

Page 33: ...s description Table Pins description Signal Pin number on Sub HD connector I O RS232 standard Description Alternative Function CTXD CT103 2 I TX Transmit serial data CRXD CT104 16 O RX Receive serial...

Page 34: ...acts as an output If an external RESET is not required it may be left unconnected Table Pin description Signal Pin number on Sub HD Connector I O Type Description RESET 14 I O SCHMITT Reset Modem WAR...

Page 35: ...are feature 7 8 Audio The audio interface is a standard interface for connecting a telephone handset Echo cancellation and noise reduction features are also available to improve the audio quality in h...

Page 36: ...he table Speaker gain verses Max output voltage in the Wavecom AT Commands Interface Guide The loud speaker may be connected directly to the output pins The amplifier gain may be adjusted from between...

Page 37: ...0 0 25 8 12 12 1 0 5 0 5 9 15 15 2 1 1 10 18 18 3 1 5 1 5 11 24 24 4 2 2 12 30 30 5 3 3 13 36 40 6 6 6 14 42 infini 7 9 9 15 infini infini duration duration of the tone in 100ms steps The range is fr...

Page 38: ...Characteristics 8 1 Mechanical Table Mechanical characteristics Dimensions 73 x 54 5 x 25 5 mm excluding connectors Overall Dimensions 90 x 54 5 x 25 5 mm Weight 95 grams modem only 197 grams modem fi...

Page 39: ...d by an internal varistor The modem is then protected by the in line fuse The table below indicates the power supply consumption of the modem without the RS232 connected Table Consumption 1 without RS...

Page 40: ...V pp AC voltage Loud speaker output current load 150 1nF 16 mA Absolute loud speaker impedance 32 50 Impedance of the loud speaker amplifier in differential mode 1 10 Table Characteristics of the inte...

Page 41: ...Speaker output current max 80 mA Command voltage VCE 32 V Table Example of a transducer tested with the GenPro Buzzer characteristics Values Type Transducer KINGSTATE KX 1612 Power consumption 6 18V...

Page 42: ...le Characteristics of the inputs diode of opto coupler Caract ristiques Symboles Conditions Min Typ Max Unit Courant max IF rms 50 mA Tension inverse max VR 5 V Tension directe VF IF 10 mA 1 0 1 15 1...

Page 43: ...Unit Tension max VCE0 Emetteur ouvert 80 VDC Tension max VCES VBE 0 V 60 VDC Courant collecteur IC 1 A Tension saturation VCEsat IC 500 mA 1 3 V Dissipation PTtot Tamb 25 C Tj 110 C 0 78 W Typical ou...

Page 44: ...fications Table RESET signal operating conditions Parameters Min Max Condition VT 1 1 V 1 2 V VT 1 7 V 1 9 V VOL 0 0 4 V IOL 50 A VOH 2 0 V 2 8 V IOH 50 A VT VT Hysteresis thresholds 8 2 6 GSM DCS 8 2...

Page 45: ...er Maximum output power E GSM 900 at ambient temperature Maximum output power E GSM 900 at ambient temperature Maximum output power E DCS 1800 at ambient temperature Maximum output power E DCS 1800 at...

Page 46: ...the following requirements R TTE 1999 5 EC Directive Regulations of standard ETSI EN 301 489 7 02 95 54 EC Automotive Directive E24 10R 02050 E mark 2002 96 CE DEEE crossed out wheelie bin It also con...

Page 47: ...fuse type is FSD 2 5 A 250 V FAST 8 5 2 Over voltage The modem is protected against voltages over 32 VDC When the supply voltage exceeds 32 VDC the power supply is cut in order to protect the internal...

Page 48: ...be in use Restrictions of use of radio operator equipment in Fuel depots Chemical factories Locations where demolition is under way Other places where signs indicate that the use of cellular telephone...

Page 49: ...e The suggestions below will help you to look after and preserve this product for many years Do not expose the modem to the extreme environments such as a high temperature or a high humidity content D...

Page 50: ...GenPro modem are shown on our Internet site in the section Products Accessories For more information contact our sales department 11 Client support ERCO GENER ensures customer support for all sold mod...

Page 51: ...N 55022 1994 Conducted disturbance measurement EN 61000 4 2 1995 Electrostatic discharges immunity EN 61000 4 3 1996 Radiated radio frequency disturbances immunity EN 61000 4 4 1995 Fast transient bur...

Reviews: