![Erato Pony PS9 User Manual Download Page 35](http://html1.mh-extra.com/html/erato/pony-ps9/pony-ps9_user-manual_2421466035.webp)
Page.
35/55
•
(2) Decreasing the temperature by 1 °C;
5.2.7.2.
Changing the power level:
Is done by buttons (5) and (6):
•
(5) Increasing the power level by 1 ;
•
(6) Decreasing the power level by 1 ;
EXPLANATION: The power level can be changed in diapason from 1 to
5
The remote control has the same functions;
5.2.7.3.
Changing other parameters from the control unit
Is done by choosing the desired menu and then changing the parameters.
EXPLANATION: – The service parameters are protected by
password/combination of buttons. That password is given to the service
personnel only. IT IS PROHIBITED CHANGING THE SERVICE
PARAMETERS BY THE END USER. ;
5.2.8.
Nominal operation mode of the stove.
After the stove is ignited and the room is heated we can assume that the
stove works in nominal regime and we can perform the so called “HOT
TESTS”.
EXPLANATION:
•
In nominal regime the stove periodically cleans the ash remains in the
burner. That is done by lowering the heat power to minimum (the fuel
is consumption is at minimum) and increasing the RPM of the smoke
suction fan (air with increased debit is delivered in the burner and that
leads to full combustion of the material and also is blowing the
remaining ash residue. The time interval between cleaning is changed
by a service parameter. That means that only service personnel can
change it. During cleaning the heat power is decreased.
•
If the stove is used to heat brooms with low temperature less than 10
o
C
is recommended the stove to be at minimum power in order to easy
heat the room and to prevent thermal shocks to the hot surfaces;