EXPLANATION:
•
It is recommended the stove to be placed as close to the chimney as
possible so you can minimize the use of elbows and fittings.
•
It is prohibited the use of the stove connected to a chimney already used
by another appliance. The stove must be connected to independent
chimney.
•
When making the smoke exhaust tract you must check the following.
o
The connecting tract must be with cylindrical shape. The
diameter of the tract must be equal or larger that the diameter of
the exhaust of the stove. The chimney and the tract must be well
insulated in order to prevent cooling of the smoke gases and
decrease in the draught.
o
You must check the strength of the tract. It needs to be without
holes or cracks.
o
The inside surface of the tract needs to be as smooth as possible.
If you use elbows they must be with the maximum possible
radius of curvature, not smaller than twice the diameter of the
tract. In cases of use of long curvatures they need to be with
minimum difference from the straight shape.
o
When building the chimney you need to make it easy for
disassembly for cleaning and you need to install condense tubs.
o
The exit section of the chimney must be realized in a way
preventing entering of hail, snow or other. And also in event of
strong wind to prevent returning of smoke gases to the building.
o
The chimney needs to be wind-proof. The exit must be above
the highest point of the roof. The exit of the chimney needs to be
away of other buildings.
•
The automated hot air pellet stove „ERATO Pony PS9” is different
from the stoves with manual fuel loading – the stove is equipped
with flue gas fan creating under pressure in the burning chamber.
The exit of the chimney is with over pressure, this requires the
chimney to be well packed with heat resistant silicon (up to 250
o
C). The connection with the chimney must be done in a way that in
cases of cleaning and maintenance will not require to be removed.
It is recommended the tract to be made from stainless steel. (Mark
AISI 316) with minimum thickness of 1.0mm. The diameter is
recommended to be 80 or 100mm. It is also recommended the use
of pre insolated pipes (double wall pipes). The making of doors,