![Erato Pony PS9 User Manual Download Page 16](http://html1.mh-extra.com/html/erato/pony-ps9/pony-ps9_user-manual_2421466016.webp)
Page.
16/55
•
The Stove needs to be installed on a floor with required strength and fire-
resistance. In case of not meeting these requirements you need to chose
other place for installing the stove or to take the necessary actions in order
to improve the place for installation in order to meet the requirements.
Most often the stove is installed on fire-proved floors with size larger than
the stove itself so safety operation is ensured and possibility of fire is
taken to the minimum and also provides easy access for cleaning and
maintenance. The minimum size of the fire-proved floor needs to be
150mm from the sides of the stove and at least 300mm in front of the
stove. In case of using a metal sheet for meeting above mentioned safety
requirements it needs to be at least 2mm thick.
•
It is strongly recommended burning objects (wood beams, furniture,
curtains and flammable liquids) to be placed on distance at least 1meter
from the zone of intensive heat radiation. In cases that such objects are
near to the stove, you need to protect them with a lair of fire-prove
insulating material. If the floor is made of flammable material (wood) it is
necessary in front of the stove to be placed protective sheet with size
300mm minimum.
•
Before entering the stove in service you need to check the draught of the
chimney and to ensure that the stove is properly connected to the
chimney.
•
Maintenance procedures of the boiler should be performed by trained
adult persons, which have read the user manual of the unit;
Installation procedure of the stove requires engineering project for the
heating system, prepared according to the acting local norms and
recommendations as follows:
•
To the heating system - EN 303-5/2000 - „Heating boilers. Part 5 :
Heating boilers for solid fuels, hand and automatically fired, nominal
heat output of up to 300 kW. Terminology, requirements, testing and
marking”;
•
To the chimney;
•
Fire prevention requirements;
•
To the power circuit - EN 60335-1/1997- “Household and similar
electrical appliances – safety, Part 1 – General requirements”;