4.5. Installation

4.6. Jamming Detection

Remove the fixing screw from
the bottom edge of the Siren
housing and carefully remove
the front cover.

Hold the mounting plate in
position and mark the positions
of the four mounting holes.
There is a Spirit Level inside
the case to help ensure that 
the Siren is level. 

Drill four holes in the wall and 
insert the wall plugs. Insert the 
screws through the backplate
holes and screw them into the 
wall plugs.

Hinge the front cover locating tabs 
over the top edge of the backplate 
and carefully push the base of the 
siren cover into place. Secure the 
siren cover in place by refitting the 
fixing screw in the bottom edge of 
the cover.

1

2

1

3

4

If the Siren has been fitted as a standalone system, additional accessories can easily be 
learnt to the Siren without the need to dismount the Siren from the wall, as follows:
Press [    ] on the Remote Control 3 times (within 5 seconds) to enter Test Mode.
Press [    ] 3 times (within 5 seconds) to enter Learn Mode. A long beep is heard from 
the Siren indicating that it is in Learn Mode. 
Press the Test Button on the additional Accessory or trigger the Accessory once.
The Siren will beep again to indicate that the Accessory has been successfully connected 
with the Siren.
Press [    ] on the Remote Control to exit Learn Mode, it will emit one beep. 
The System is now Armed, press Unlock to Disarm the System.

Enter/Exit Learning Status using a connected Remote Control 

4.

6.

5.

3.

2.

1.

Test Mode prevents the Siren’s tamper switch from triggering an alarm during 
maintenance or when changing the battery.
When the Remote Control is connected with the Siren, press [    ] 3 times (within 5 
seconds) to enter Test Mode, the Siren will emit a long beep indicating that the system 
is now in Test Mode. During this period the Siren will not alarm but will beep if the 
tamper switch or the connected sensors are triggered.
Press [    ] on the Remote Control to exit Test Mode after a short beep.
The System is now Armed. Press Unlock to Disarm the System.

Test Mode

4.

3.

2.

1.

Jamming Detection will activate if the Siren receives a constant signal for 30 seconds or 
3 lots of 10 seconds within a 5 minute period. If detected, the Siren will emit 10 seconds 
of short beeps, if the signal is still detected, a full Alarm condition will occur.
We recommend that you wait up to 30 days before activating the Jamming Detection 
feature to allow time for you to become familiar with the operation of your Alarm System.

Note:

 Jamming Detection is disabled by system default.

Please note: pressing the rear anti-tamper switch 7 times will also enter test mode.

Page 10

Summary of Contents for VALIANT

Page 1: ...INSTALLATION AND OPERATING MANUAL Version 1 0 VALIANT Solar Siren Alarm Kit ...

Page 2: ...ERA VALIANT Red Lens DoP No EM0017 ...

Page 3: ...ion of ERA Home Security Disposal and Recycling Disposal of this product is covered by the Waste Electrical or Electronic Equipment WEEE Directive It should not be disposed of with other household or commercial waste At the end of the product s useful life the packaging and product should be disposed of via a suitable recycling centre Please contact your local authority or the retailer from where ...

Page 4: ...your product 2 2 PCB Layout 2 3 Installation 4 1 Positioning 4 2 PCB Layout 4 3 Jumper Setup 4 4 Usage 4 5 Installation 4 6 Jamming Detection 6 Notes 12 ERA Product Guarantee 13 5 Specification 4 Solar Charged Siren 3 1 Get to know your product 3 2 Buttons Functions 2 Magnetic Door Window Sensor 3 Remote Control Kit Contents 3 3 3 3 4 4 4 4 5 5 6 6 7 7 7 8 8 8 8 9 10 10 11 Page 2 ...

Page 5: ...acket Slot 5 Self adhesive pad fixing markers Flashes every 2 seconds Self testing state Flashing twice Self testing finished enters working mode Flashes once Movement is detected Flashes once every 3 seconds Low battery indication immediate battery change required 1 1 Get to know your product KIT CONTENTS 1 PIR MOTION DETECTOR 1 2 3 4 5 1 2 LED Indication Page 3 ...

Page 6: ...of the PIR The LEDs will then flash once when movement is detected for up to 3 minutes 3 2 1 2 1 Infrared Sensor Detects movement and triggers an alarm signal when the system is armed Tamper Switch If the casing is opened when in working state the tamper switch will be triggered and generate an alarm signal 1 3 PCB Layout 1 5 Working Mode 1 4 Test Mode AA 1 5V LR6 Infrared Sensor Zone Setting Tamp...

Page 7: ...the room The LED indicator will flash once when motion is detected 2 a b 2m Status Indicator Magnet Transmitter Suitable for fitting to doors windows and any object that opens and closes The Window door sensor transmits a signal to the control panel siren when contact is broken between the transmitter and the magnet Transmits a low battery signal to the ERA alarm control panel Where possible mount...

Page 8: ...o the back of the transmitter Peel off the other side of each adhesive strip Mount the magnet on the door and the transmitter on the door frame with less than a 1cm separation between the two When opening the door a small red indicator lights up briefly this indicates that the transmitter has sent a signal to the control panel 2 3 Installation 4 3 2 1 Tamper Switch Battery Zone Setting Note Please...

Page 9: ...ute Disarm Press to arm the control panel siren and all of the accessories Full Arm Press to disarm the system Press to part arm the alarm system for systems with control panels only Press to activate the panic alarm SOS Press to arm the system with the solar siren in muted silent mode Press to disarm the system with the solar siren in mute silent mode Note 1 For Mute Arm Mute Disarm operation pre...

Page 10: ...hich is relatively inaccessible to an intruder The Siren is designed to work on any aspect wall however for optimum performance try to avoid installing on a north facing wall or to a wall with shadows cast by other buildings trees and roof overhangs For optimum radio signal reception mount the Solar Siren to Maximum distance of one metre from any external or internal metalwork drainpipes gutters r...

Page 11: ...ion of an alarm event Connecting to a Control Panel 5 4 3 2 1 When installed as a Siren only Alarm System without a Control Panel all of the Alarm Accessories must be registered to the Siren Connecting a Wireless Accessory to the Siren Press the Learn Button on the Solar Siren 0 5 seconds the system goes into Learn Mode after one beep is heard Press the Test Button on the Accessory or trigger the ...

Page 12: ...ry has been successfully connected with the Siren Press on the Remote Control to exit Learn Mode it will emit one beep The System is now Armed press Unlock to Disarm the System Enter Exit Learning Status using a connected Remote Control 4 6 5 3 2 1 Test Mode prevents the Siren s tamper switch from triggering an alarm during maintenance or when changing the battery When the Remote Control is connec...

Page 13: ...rea 25kg 433MHz ABS Plastic Temperature 10 C 55 C Humidity 80 non condensing Detector 100mm x 59mm x 43mm Transmitter 52mm x 30mm x 26 5mm Model No Back Up Power Start Up Power Solar Panel Output Current Standby Current Maximum Alarm Current Standby Time Maximum Siren Volume Receiving Distance Radio Frequency Housing Material Operation Conditions Dimensions L x W x H Model No Power Supply Standby ...

Page 14: ...rective It should not be disposed of with other household or commercial waste At the end of its useful life the packaging and product should be disposed of via a suitable recycling centre Please contact your local authority or the retailer from where the product was purchased for information on available facilities Page 12 ...

Page 15: ...acement of parts due to fair wear and tear 2 Abuse or misuse including but not solely limited to the failure to use this product for its normal purposes or in accordance with ERA s instructions on usage and maintenance 3 Failure of the product arising from incorrect installation or use not consistent with the instructions supplied and the cost of any removal or installation of products 4 Accidents...

Page 16: ...Customer Helpline 0345 257 2500 www erahomesecurity com ERA Home Security Ltd Valiant Way Wolverhampton West Midlands WV9 5GB email support erahomesecurity com ...

Reviews: