“AGUATEST” PROCEDURE FOR MEASURING WATER HARDNESS, COMPONENT REF.– SV0011200
9
9
Before taking the sample let the water run for aprox. 1
min.
Fill the test tube with water to the white line
Add two drops of the dark solution, agitate and the water
takes on a violet colour
Next add the white solution (b) drop by drop, shaking it
after each addition, until it suddenly assumes a light blue
colour
Count the number of drops of the white solución (b)
With the chart for the “AGUATEST” procedure from the
no. of drops obtained from solution (b) the degree of
water hardness can be measured.
Example : 9 drops = 9º DH (German degrees)
9 drops = 16.07 HF (French degrees)
Select any programme
Open the dishwasher door and leave the door micro
activated
Start the machine with door open and wait until it begins
to take in water
Let it take in water for approximately 15 sec.
Then the steam outlet is in its turn at the same point as
the water intake
Water intake from mains
Water intake in the interior of the tub
24.