WATER LEVEL CONTROL SYSTEM
8
8
Irregular water intake
Insufficient water
Washes badly and the machine stops
Take off the right side panel
Start water intake with programme selected (prewash)
Is a sudden rise of water
observed through the compression
chamber from the beginning
of the intake?
Circuit from compression chamber to
ballcock blocked
T R EATMENT
§
Check ballcock and clean it.
§
Replace black conduits (chamber-ballcock /
ballcock –tub)
§
Check and clean bottom of housing in tub
NO
YES
Water rise in the chamber is normal, but the presostat
connects before reaching its level.
§
Review the connections and inside of the transparent tube.
Presostat-chamber
§
Change presostat
Excess water
Take off right side panel
§
Take in water by selecting a prewash.
§
Observe the water’s behaviour in the
compression chamber.
Just before connecting
the preostat is a sudden rise
in the water level
observed ?
Defective ballcock
NO
YES
T R EATMENT
§
Check for dirt and clean
§
If nothing strange is noted in the
ballcock, replace the ballcock
After this it continues taking in water
- Presostat conduit blocked
- Presostat conduit with water
- Defective presostat
NOTE : Presostat settings come calibratred and factory sealed so that any manipulation of these apart from achieving no objective would disturb the appliance’s correct functioning, and therefore its manipulation is prohibited.
minimum 4.7 L.
WATER LEVELS – 96 R Example : LV-25, 35, = 4.75 L
The tub axis has two indicative marks between which the water level should be maintained – The element is not covered with water
WATER LEVELS 88 R. Example : LV-93 – 95 = 7 litres : The level is considered correct when the water reaches or is at a level between the decalcifier screw and the salt deposit cap – The element is covered with water
Test the machi ne wi th a new intake
23.