OPERATOR INSTRUCTION MANUAL
IM-HPccSD_Rev05
HP350SD; HP550SD;
HP1000SD
DOUBLE ACTING HYDRAULIC
SEALED HAND PUMPS
7
4.
HAND PUMP
MAINTENANCE
4.1
INSPECTION
A thorough inspection should be carried out prior
to usage, storage or transportation to ensure the
completeness and condition of the hand pump.
Inspection should include:
•
visual inspection of the outer parts of the hand
pump, checking for obvious damage, degradation
or missing parts.
•
visual inspection of the couplers and gauges,
checking for obvious damage and degradation.
4.2
CLEANING
To lightly clean the pump, wipe gently with a damp
cloth.
If more thorough cleaning is required (for example
following immersion in water) carry out the following
cleaning procedure:
•
strip the tool down, observing the schematics in
section 8
•
clean the components using detergent, following
the manufacturer’s guidelines
•
rinse the components to remove traces of
detergent
•
dry the component thoroughly
Inspect, service and lubricate the tool immediately
after the cleaning process.
4.3
MAINTENANCE
Replace missing, worn or damaged parts. Use only
genuine Equalizer parts from approved distributors
or service centres. Equalizer parts have been
engineered and manufactured to be fit for purpose.
Lubricate all moving parts with light machine oil.
If topping or replacing hydraulic oil as part of a
service, use only premium quality hydraulic oil of the
grade 15 cSt.
4.4
STORAGE & TRANSPORTATION
Equalizer Hand Pumps should be stored in a cool,
dry place. Tools should always be cleaned, serviced
and lubricated prior to storage. Ensure that tools are
stored in their designated packing cases.
4.5
SUB-SEA USAGE
The Equalizer range of HP hydraulic hand pumps are
fitted with a sealed-bladder type reservoir system
that allows for sub-sea operation.
Please contact Equalizer International for instruction
sheet.