![eQ-3 MAX! Eco Taster Operating Manual Download Page 21](http://html1.mh-extra.com/html/eq-3/max-eco-taster/max-eco-taster_operating-manual_2420433021.webp)
21
8. Teach-out/Reset
The MAX! Eco switch can be reset to the initial state man-
ually. Restoring the initial state deletes all settings and in-
formation about taught-in devices.
Before you reset the MAX! Eco switch to the factory
settings, first delete the device from the MAX! soft
-
ware.
•
First remove the batteries from the battery compartment.
•
Wait 60 seconds.
•
Press and hold down the button at the top or bottom.
•
Re-insert the batteries at the same time.
•
Press and hold down the button until the device LED
starts to flash.
•
Release the button. The factory settings are restored.
9. LED flashing sequences and
transmission behaviour
The LED’s flashing sequences have different meanings:
Flashing sequence
Meaning
1x flash
Confirmation following successful sending
of the radio command
2x flashes
Duty cycle has been exceeded. The longest
period to wait before sending again would
be an hour.
3x flashes
Error message, radio command not sent
successfully