54
55
Further details can be found in chapter 8.
A battery symbol (
) indicates that the batteries need
to be replaced. After removing the batteries, wait approx.
1 minute before inserting the new ones. This device does
not support battery operation.
The service life of new alkaline batteries is approx-
imately two years.
Using rechargeable batteries is not possible.
Never recharge standard batteries. Doing so will
present a risk of explosion. Do not throw the batter-
ies into a fire. Do not short-circuit batteries.
6. Setting date and time
After inserting or replacing batteries, the firmware version
number will be showing briefly. Following this, date and
time will be requested automatically.
•
Set the year, month, day, hour and minute with the hand-
wheel and confirm with the boost button. The motor
moves the control pin backwards during the setting of
date and time.
•
If „InS“ and the rotating activity symbol „
“ are dis-
played, the motor still reverses. If only „InS“ is shown in
the display, the MAX! radiator the can be moun-
ted on the valve.
The MAX! Radiator The
can be configured alrea
-
dy before installation. Therefore, press auto/manu while
„InS“ is displayed. For further details, please see section
„14. Configuration menu“. After finishing configuration,
„InS“ is displayed again and the MAX! radiator thermo-
stat+ can be mounted.
7. Mounting on a radiator
The MAX! radiator the is easy to install, and can
be done without draining heating water or intervening in the
heating system. No special tools are required, nor does the
heating have to be switched off.
The union nut attached to the MAX! radiator the
can be used universally and without accessories for all
valves with a thread size of M30 x 1.5 from the most popular
manufacturers such as
•
Heimeier
•
MNG
•
Junkers
•
Landis&Gyr (Duodyr)
•
Honeywell-Braukmann
•
Oventrop
•
Schlösser
•
Comap
•
Valf Sanayii
•
Mertik Maxitrol
•
Watts
• Wingenroth (Wiroflex)
•
R.B.M
•
Tiemme
•
Jaga
•
Siemens
•
Idmar