SERVICE MANUAL EIS 165.3 N/P KW (short version) inglese
Autori: Serralunga M.
14/10/2021
9
NO COPYING IN ANY FORM WITHOUT WRITTEN PERMISSION FROM EPTA QUALITY MANAGEMENT
2.4
VIEW OF THE EVAPORATOR COMPARTMENT AND RELEVANT
PIPEWORK - EIS 165.3 N/P KW
3. POSITION OF PROBES IN THE CABINET
There are two probes in the EIS 165 N/P KW model.
Model
Position of probe
Probe
Colour
Function
Probe Epta code
EIS 165 N/P KW
Evaporator
Tank – motor compartment
Yellow
Grey
Defrost
Display - Thermostat
I0205786
I0205805
GUTTER SERPENTINE
GUTTER SEPRENTINE –
SOLENOID VALVE
SUNCTION PIPE –
EVAPORATOR OUTLET
CAPILLARY –
EVAPORATOR INPUT
DEFROST PROBE
GUTTER SEPRENTINE –
SOLENOID VALVE
SUNCTION PIPE –
EVAPORATOR OUTLET
Position of probe
touching
Position of probe
touching