Ethernet Setup Mode
This mode restores the Ethernet interface settings to the factory-default settings.
Follow the steps below.
1
After running a self-test, hold down the Feed button for at least one second to enter
the Mode selection.
The Mode selection guidance is printed, and the Paper LED flashes.
2
Briefly press the Feed button three times (less than one second), hold it down for at
least one second to enter the Interface Setup mode.
The guidance is printed.
3
Briefly press the Feed button once (less than one second), hold it down for at least
one second. (Hold down the Feed button until the message of Resetting to Factory
Default is printed.)