![Epson TM-C100 Technical Reference Manual Download Page 47](http://html.mh-extra.com/html/epson/tm-c100/tm-c100_technical-reference-manual_2418723047.webp)
Rev. C
Product Specifications of the TM-C100
A-1
TM-C100 Technical Reference Guide
Appendix A
Product Specifications of the TM-C100
A.1 Product Specifications
Item
Specification
Interface (compatible)
USB
Power supply
Power supply with a dedicated AC adapter
Input voltage (rated)
Input voltage (rated) 90 (100 - 10%) to 264 (230 + 15%) VAC
Frequency (rated)
47 to 63 Hz
Power consumption
Operating
Idling
Average:
Approximately 11 W
Peak:
Approximately 13 W
Average:
Approximately 1 W
Applicable standards
Europe:
CE marking EMC Directive: 89/336/EEC
EN55022 Class B
EN55024
IEC61000-4-2
IEC61000-4-3
IEC61000-4-4
IEC61000-4-5
IEC61000-4-6
IEC61000-4-11
Safety standard: TÜV (EN 60950)
North
America:
EMI: FCC/ICES-003 Class A
Safety Standard: UL 60950/CSA C22.2 No. 60950
Oceania:
EMC: AS/NZS 3548/CISPR22 Class B
Japan:
EMI: VCCI Class A
Reliability
Product
lifetime:
Mechanism 12,000,000 passes (6,000,000 carriage returns)
Print head 1,600,000,000 shots/nozzle
(Shots are the numbers of pulses energized for the print
head.)
Autocutter
Plain paper, special fine paper 350,000 cuts
Special matte paper, plain borderless label paper
200,000 cuts
ASF 200,000
sheets
(The end of product lifetime is when the printer reaches
the start of the wear-out failure period.)
MTBF
180,000 hours (Failure is defined as a random failure occurring during the random
failure period.)
MCBF
30,000,000
passes
This is an average failure interval based on failures relating to wearout and random
failures up to the life of 12,000,000 passes.
Temperature and humidity
Printing:
Storage:
10 to 35ºC, 20 to 80% RH no condensation
Packaged for shipping
–
20 to 60ºC, 5 to 85% RH no condensation
(Ink not loaded)
(within 120 hours at
–
20ºC or 60ºC)
Ink loaded
–
20 to 40ºC, 20 to 85% RH
Absolute maximum rated
temperature
70ºC (This temperature must NOT be exceeded whenever it is operating or in
storage.)
Pressure (elevation)
Printing:
Operating:
775 to 1,050 hPa (corresponding to 0 to 2,000 m above sea level)
700 to 1,060 hPa (corresponding to 0 to 2,500 m above sea level)
Summary of Contents for TM-C100
Page 1: ...TM C100 Technical Reference Guide EPSON English 410000602 ...
Page 2: ......
Page 44: ...3 14 Using the Printer Rev C ...
Page 63: ......
Page 64: ...EPSON SEIKO EPSON CORPORATION ...