EPSON Stylus Scan 2000
Revision A
Disassembly & Assembly
Disassembly Procedures
115
4.2.5.8 Removing the PE Paper Detector Assembly
1.
Remove the housing. (Refer to Section 4.2.1.)
2.
Move the carriage out of the home position.
3.
Release two fixed hooks securing the PE detector assembly from the back of the frame
and remove the PE detector assembly, sliding it upward. Remove the PE board
assembly and PE lever, if necessary.
Figure 4-19. Removing the PE Detector Assembly
During assembly, make sure that the tip (sensor part) of the detector
lever is in the hole of paper guide assembly.
After releasing two hooks, remove the PF
paper detector assembly, sliding it
upward.
(From back side of the
frame)
PE Holder
This side should be
installed on the
frame.
Torsion Spring 0.22
PE Lever
PE Board
Assembly
Summary of Contents for Stylus Scan 2000
Page 1: ...EPSON EPSON EPSON France S A Stylus SCAN 2000 SERVICE MANUAL PRODUIT ...
Page 2: ... SEIJ99006 SERVICE MANUAL EPSONSTYLUSScan2000 All in one printer scanner and copier ...
Page 9: ...C H A P T E R 1 PRODUCTDESCRIPTION ...
Page 30: ...C H A P T E R 2 OPERATINGPRINCIPLES ...
Page 62: ...C H A P T E R 3 TROUBLESHOOTING ...
Page 84: ...C H A P T E R 4 DISASSEMBLY ASSEMBLY ...
Page 118: ...C H A P T E R 5 ADJUSTMENT ...
Page 133: ...C H A P T E R 6 MAINTENANCE ...
Page 144: ...C H A P T E R 7 APPENDIX ...
Page 155: ...Stylus Scan 2000 Revision A Appendix Exploded Diagrams 154 ...
Page 156: ...Stylus Scan 2000 Revision A Appendix Exploded Diagrams 155 ...
Page 157: ...Stylus Scan 2000 Revision A Appendix Exploded Diagrams 156 ...
Page 158: ...Stylus Scan 2000 Revision A Appendix Exploded Diagrams 157 ...
Page 159: ...Stylus Scan 2000 Revision A Appendix Exploded Diagrams 158 ...