Use
or
to highlight a menu option and press
Then enter the correct track information. When the bad
track list is correct, highlight
Save and Exit
and press
Note
When you run the Media analysis test, the program
automatically marks the bad tracks when it formats the disk.
Start
and end cylinder
numbers
The program displays the following prompts for the starting
and ending cylinder numbers:
Start cylinder number ?
0
End cylinder number ?
nnn
Enter the first and last cylinder numbers on which you want to
perform the tests. The default for the start cylinder number is 0,
and the default for the end cylinder number is one less than the
highest cylinder number of your hard disk. For example, on the
40MB hard disk, the highest cylinder number is 976.
Start
and
end
head numbers
The program displays the following prompts for the starting
and ending head numbers:
Start head number
?
0
End head number
?
nn
Enter the first and last head numbers on which you want to
perform the tests. The default for the start head number is 0,
and the default for the end head number is one less than the
highest head number of your hard disk. For example, the
default end head number for the 40MB disk is 4.
After you specify the hard disk parameters, press
and
at
the
Proceed
prompt to run the test.
B-16