4. Troubleshooting (DeviceNet)
4.1.3.6.2 Verifying the DeviceNet network condition
The applicomIO Console application has a network diagnostic function
(Diagnostic). The procedure for using the Diagnostic is described below.
(1) Open the Diagnostic window, click the magnifying grass button, and select the
“Channel” on the device tree in the left side of the window. The window
changes as shown below.
The
CAN
and
DeviceNet (scanner)
tabs appear on the data display in the right
side of the window.
The CAN controller status of the scanner board is displayed on the
CAN
tab.
Rx
: Number of receive data bytes and flames
Tx
: Number of send data bytes and flames
OverRun : Number of communication overrun errors detected by CAN
controller
Errors
: Number of communication errors detected by CAN controller
Bus Off : Number of Busoff detections
Baud Rate :
baud rate
Bus Load : Load on the bus (maximum, minimum, current)
Use DeviceNet so that the load on a bus is under 60% of the maximum load.
When the load exceeds 60%, the DeviceNet network communication will be
unstable. (For example, more communication errors)
For the procedure for master configuration, refer to respective master device
manuals. For EPSON RC+ master configuration, refer to the section
2.5.5
Master Mode
.
)
NOTE
Fieldbus I/O Rev.6
107
Summary of Contents for EM07ZS1647F
Page 1: ...Rev 6 EM07ZS1647F EPSON RC Option Fieldbus I O ...
Page 2: ...E PSON RC Option Fieldbus I O Rev 6 ...
Page 8: ...vi Fieldbus I O Rev 6 ...
Page 12: ...Table of Contents x Fieldbus I O Rev 6 ...
Page 80: ...2 Installation 68 Fieldbus I O Rev 6 ...
Page 88: ...3 Operation 76 Fieldbus I O Rev 6 ...
Page 164: ...5 Maintenance Parts List 152 Fieldbus I O Rev 6 ...
Page 168: ...Appendix A applicomIO Upgrade 156 Fieldbus I O Rev 6 ...