EB-E01 series
Troubleshooting
INTERNAL USE ONLY
SEIKO EPSON
41
Revision A
AUTO IRIS ERROR/POWER SUPPLY (BALLAST) ERROR
LAMP ERROR
LED Status
Corresponding error name
Remedy
Reference
Power
Status
Lamp
Temp
Wireless LAN
Auto Iris: Auto Iris Error
If the same error occurs after turning the power back on, check
the error name and carry out the remedy referring to the reference
on the right column.
Ballast: Power Supply (Ballast) Error
LED Status
Corresponding error name
Remedy
Reference
Power
Status
Lamp
Temp
Wireless LAN
Cover Open: Lamp Cover open Error
Lamp: Lamp Error
Lamp On: Lamp Lit Error
Lamp Off: Lamp Failure
Check if the Lamp Cover is
installed correctly.
If not, reinstall the Lamp Cover
correctly.
Check if the Lamp is installed
correctly.
If not, reinstall the Lamp Cover
correctly.
Take out the lamp and check if
the Lamp is cracked or
damaged.
If the Lamp is not broken,
reinstall it and turn the power
back on. If the error recurs,
replace the Lamp with a new
one.