FAN ERROR/SENSOR ERROR
HIGH TEMPERATURE ERROR/AIR FILTER FLOW REDUCTION ERROR
LED Status
Corresponding error name
Remedy
Reference
Power
Status
Lamp
Temp
Wireless LAN
Fan: Fan Error
Thermistor: Sensor Error
Check the connections between each fan/sensor and MA Board.
If any connection failure is found, correct it.
If the same error occurs when turning the power back on after
trying the remedy above, check the error name and carry out the
remedy referring to the reference on the right column.
LED Status
Corresponding error name
Remedy
Reference
Power
Status
Lamp
Temp
Wireless LAN
Temp: High Temp Error
1. Check the Air Filter's condition (dirt accumulation,
clogging). When clogging or similar is found, clean/
replace the filter.
2. If the same error occurs when turning the power
back on after trying the remedy above, check the
error name and carry out the remedy referring to the
reference on the right column.