Revision A
3.3.11.1 Auto Iris Assy
DISASSEMBLY PROCEDURE
1. See
and remove all parts up to the component below from
the projector.
2. Remove the two screws ( ) and remove the "Auto Iris Assy".
Before attaching or removing the "Auto Iris Assy", move
the Auto Iris Blades to the home position by inserting a
Phillips screw driver (No0) into the holes shown in the
figure below.
Screwdriver insertion positions
Home position
Auto Iris Blades
Auto Iris Assy