Epson DFX-9000 Field Repair Guide
3/29/07
Adjustments
Printer Component,
Software Item,
LCD Display,
Printer Button
Page 173.
9.
Move the
Print Head
to Column 70 of the
Column Scale Bar
.
10. Slide a .40mm feeler gauge between the
Platen
and the nose of the
Print Head
. It might be necessary to use 2
or more size gauges to add up to .40mm.