EPSON AcuLaser C8500
Revision C
Disassembly/Assembly/Adjustment
Disassembly/Assembly Procedures
3-53
3.2.9.8 ERASE LAMP ASSY (PL6.1.30) Removal
1.
Remove the TOP COVER ASSY. (See Section 3.2.5.4.)
2.
Remove the DRUM CARTRIDGE. (See Section 3.2.9.1.)
3.
Remove the ROS ASSY. (See Section 3.2.9.3.)
4.
Remove the XL RAIL ASSY. (See Section 3.2.9.5.)
5.
Free the ERASE LAMP ASSY by pulling its harness through the hole.
6.
Unhook the ERASE LAMP ASSY from the XL RAIL with a screwdriver,
etc., and remove the ERASE LAMP ASSY.
Figure 3-58. ERASE LAMP ASSY Removal