13
Boost Charging Voltage
14.2V
14.4V
14.6V
9~17V
Float Charging Voltage
13.8V
13.8V
13.8V
9~17V
Boost Return Voltage
13.2V
13.2V
13.2V
9~17V
Low Voltage Reconnect
12.6V
12.6V
12.6V
9~17V
Under Voltage Recover
12.2V
12.2V
12.2V
9~17V
Under Voltage Warning
12V
12V
12V
9~17V
Low Voltage Disconnect
Voltage
11.1V
11.1V
11.1V
9~17V
Discharging Limit
Voltage
10.6V
10.6V
10.6V
9~17V
Equalize Duration
——
120
Min.
120
Min.
0~180
Min.
Boost Duration
120
Min.
120
Min.
120
Min.
10~180
Min.
Note:
The following rules must be observed when modify the parameters
value in user battery type (factory default value is the same as sealed type):
High Volt Disconnect > Charging limit voltage ≥ Equalization voltage
≥ Boost voltage ≥ Float voltage > Boost return voltage
High Volt Disconnect > Over Voltage Reconnect
Low Voltage Reconnect > Low Voltage Disconnect ≥ Discharging
Limit Voltage
Under Voltage Warning Reconnect > Under Voltage Warning ≥
Discharging Limit Voltage
Boost Reconnect Charging voltage
>
Low Voltage Disconnect
Summary of Contents for SPP-01