26
Fault LED indicator blink, LCD displaying ‗Current Err‘
Probable Cause: Charging current in three phases is unbalanced.
Solution: Disconnect solar modules and restart the eTracer-BND; if the fault still exists,
please contact the supplier to make maintenance.
Fault LED indicator blink, LCD displaying ‗Over Volt‘
Probable Cause: solar modular output is too high.
Solution: Check solar component parameters matching; the controller will disconnect
the input if the voltage is over 150V and will Recovery below 145V.
Fault LED indicator blink, LCD displaying ‗Over Temp‘
Probable Cause: Heat sinks operational temperature is quite high to 85 º
C or above.
Solution: The controller will automatically stop working. When the temperature is
below 75 º
C, the controller will resume to work.
Cannot connect to the controller via RS-485 or RS-232
Probable Cause: RS-485 serial baud rate setting error or serial-USB adapter incorrect
configuration.
Solution: Check serial baud rate is set to 115200bps or not and choose the right COM
port; If using a serial-USB adapter, verify that the adapter software is installed and a
serial COM port has been mapped.
5.3 Maintenance
The following inspections and maintenance tasks are recommended at least two times
per year for best controller performance.
Check that the controller is securely mounted in a clean and dry environment.
Check that the air flow and ventilation around the controller is not blocked. Clear all
dirt or fragments on the heat sink.
Check all the naked wires to make sure insulation is not damaged for serious
solarization, frictional wear, dryness, insects or rats etc. Maintain or replace the wires if
necessary.
Tighten all the terminals. Inspect for loose, broken, or burnt wire connections.
Summary of Contents for eTracer ET4415BND
Page 2: ......
Page 8: ...4 2 3 Characteristics 2 3 4 5 6 1 8 7 14 13 16 15 12 11 10 9 Figure 2 1 eTracer BND features ...
Page 33: ...29 Figure6 2 Real Time Monitoring Figure6 3 Control Parameter ...
Page 41: ...37 10 Dimensions ET4415BND Dimensions Unit mm ...
Page 42: ...38 ET6415BND Dimensions Unit mm Version V1 4 ...
Page 43: ......