21 Error and function messages
Function messages
Description
What to do?
Warning thresh.:
U/I Monitoring
Exceeding of the preset warning threshold
(only if U/I monitoring is activated)
Check the tank contacts and the
internal resistance of the tank.
Preset current respectively voltage
values are achieved?
Alarm thresh.:
U/I Monitoring
Exceeding of the preset alarm threshold
(only if U/I monitoring is activated)
Check the tank contacts and the
internal resistance of the tank.
Preset current respectively voltage
values are achieved?
Error:
Overload detected!
Overload (short circuit) on the output
detected (only at overload detection)
Check short circuit at the tank /
work piece→ check the tank!
Error messages
(in alphabetical order)
Description
What to do?
Error:
Operation relay off!
Indication relay of the power supply not
operated
Check the operating state of the
power supply:
- Main supply at the power supply
is missing
-Excess temperature
Contact service
Error:
Bus logging
Card full!
MMC/SD logging defective
(only for devices with MMC/SD card)
Install card with free memory
capacity
Error:
Bus logging
Buffer full!
MMC/SD logging defective
(only for devices with MMC/SD card)
Replace card
Without success: contact service
Error:
Bus logging
Write error!
MMC/SD logging defective
(only for devices with MMC/SD card)
Check card for correct
formatting and for free memory
capacity
RAM- Error:
„Memory check failed!”
RAM defective
Contact service
EEPROM- Error:
“Setup Error#X“
Saved setup data are defective
Reset to manufacturer setting
(see operating manual)
Without success: contact service
EEPROM- Error:
“
Config#X“
Saved configuration data are defective
Check configuration
Reset to manufacturer setting
(see operating manual)
Contact service
EEPROM- Error:
“
Setpoint Error#X“
Saved set value data are defective
Enter set values again
(continued processing possible)
Contact service
EEPROM- Error:
“
Actual Value Error#X”
Actual values lost
Contact service
(continued processing possible)
Error:
End switch 0x0000
End switch of pole changing defective
(only for devices with mechanical pole
changing)
Check the end switch of the
polechanger unit
Without success: contact service
Error:
Reference missing!
Reference voltage of the power supply is
missing
Check main supply
Check LEDs
Check wiring / connector from
control unit to power supply
Without success: contact service