![EPS EPS/HC 40030-60 Operating Manual Download Page 17](http://html.mh-extra.com/html/eps/eps-hc-40030-60/eps-hc-40030-60_operating-manual_2418432017.webp)
FMK0008970_4083-ESK_30V60A_1~230VAC_PFC_Ah_Ext-Sollwerte_X4_neutral_e.doc
18/41
8
The total counter
8.1
General description
The total counter allows the measurement of the actual current with
switchable measuring ranges ampere hours, ampere minutes, ampere
seconds, 1/10 000Ah and gram-silver, gram gold.
The actual counter reading is shown down in the display (line: “Total c.“)
Possible settings for the total counter
The following counting ranges are available:
Ah
= Ampere hours
Am
= Ampere minutes
As
= Ampere seconds
0.0001Ah
= 1 ten-thousandth part of ampere hour
gS
= Gram silver
gG
= Gram Gold (single weighted 3-weighted)
- Set decimal point
Attention
Each digit set after the decimal point reduces the digits before the
decimal point!
Example:
If you set ampere-hours with three digits after the decimal point
only two digits before the decimal point can be shown (99.999Ah).
If you set zero digits after the decimal point five digits before the decimal
point can be shown (99999Ah)
- Delete actual count
- Delete overflow indication
Attention:
The actual values (Ah, Am, As, 0.0001Ah, gS, gG) are deleted by
switching the unit or changing the decimal places!
The actual count is stored if the main switch of the unit is switched
off or if the unit is disconnected from mains.