PSB 9000 3U Slave Series
1.8.3
Specific technical data
(1 Related to the nominal values, the accuracy defines the maximum deviation between an adjusted values and the true (actual) value.
Example: a 80 V model has min. 0.1% voltage accuracy, that is 80 mV. When adjusting the voltage to 5 V, the actual value is allowed to differ max. 80 mV, which
means it might be between 4.92 V and 5.08 V.
(2 RMS value: LF 0...300 kHz, PP value: HF 0...20MHz
15 kW
Model Slave
PSB 9060-360
PSB 9080-360
PSB 9200-210
PSB 9360-120
AC Input
Voltage range (L-L), frequency
342..528 V AC
Connection
3ph, PE
3ph, PE
3ph, PE
3ph, PE
Frequency range
45 - 65 Hz
45 - 65 Hz
45 - 65 Hz
45 - 65 Hz
Fusing (internal)
6x T16 A
6x T16 A
6x T16 A
6x T16 A
Leak current
< 3.5 mA
< 3.5 mA
< 3.5 mA
< 3.5 mA
Phase current
> 0.99
> 0.99
> 0.99
> 0.99
Efficiency of energy recovery
≤ 92%
≤ 92%
≤ 93.5%
≤ 93.5%
DC terminal
Max. voltage U
Max
60 V
80 V
200 V
360 V
Max. current I
Max
360 A
360 A
210 A
120 A
Max. power P
Max
15 kW
15 kW
15 kW
15 kW
Overvoltage protection range
0...66 V
0...88 V
0...220 V
0...396 V
Overcurrent protection range
0...396 A
0...396 A
0...231 A
0...132 A
Overpower protection range
0…16.5 kW
0…16.5 kW
0…16.5 kW
0…16.5 kW
Temperature coefficient for set
values Δ/K
Voltage / current: 100 ppm
Capacitance (approx.)
23970 μF
23970 μF
7560 μF
1170 μF
Voltage regulation (general)
Adjustment range
0...61.2 V
0...81.6 V
0...204 V
0...367.2 V
Accuracy
(1
(at 23 ± 5°C)
< 0.1% U
Max
< 0.1% U
Max
< 0.1% U
Max
< 0.1% U
Max
Line regulation at ±10% ΔU
AC
< 0.02% U
Max
< 0.02% U
Max
< 0.02% U
Max
< 0.02% U
Max
Remote sensing compensation
Max. 5% U
Max
Max. 5% U
Max
Max. 5% U
Max
Max. 5% U
Max
Voltage regulation (power supply)
Load regulation at 0...100% ΔI
OUT
< 0.05% U
Max
< 0.05% U
Max
< 0.05% U
Max
< 0.05% U
Max
Rise time 10...90%
ΔU
OUT
Max. 30 ms
Max. 30 ms
Max. 30 ms
Max. 30 ms
Transient time after ΔI
OUT
< 1.5 ms
< 1.5 ms
< 1.5 ms
< 1.5 ms
Ripple
(2
< 320 mV
PP
< 25 mV
RMS
< 320 mV
PP
< 25 mV
RMS
< 300 mV
PP
< 40 mV
RMS
< 320 mV
PP
< 55 mV
RMS
Voltage regulation (el. load)
Load regulation at 0...100% ΔU
< 0.05% U
Max
< 0.05% U
Max
< 0.05% U
Max
< 0.05% U
Max
Current regulation (general)
Adjustment range
0...367.2 A
0...367.2 A
0...214.2 A
0...122.4 A
Accuracy
(1
(at 23 ± 5°C)
< 0.2% I
Max
< 0.2% I
Max
< 0.2% I
Max
< 0.2% I
Max
Line regulation at ±10% ΔU
AC
< 0.05% I
Max
< 0.05% I
Max
< 0.05% I
Max
< 0.05% I
Max
Current regulation (power supply)
Load regulation at 0...100% ΔU
OUT
< 0.15% I
Max
< 0.15% I
Max
< 0.15% I
Max
< 0.15% I
Max
Current regulation (el. load)
Load regulation at 0...100% ΔU
IN
< 0.15% I
Max
< 0.15% I
Max
< 0.15% I
Max
< 0.15% I
Max
Ripple
(2
< 240 mA
RMS
< 240 mA
RMS
< 66 mA
RMS
< 50 mA
RMS