41
Code
Cause
Solution
E12
The temperature of circuit
board is too high.
Stop operating the outboard and wait until
the temperature falls within the normal
operating temperature range.
E22
MCU Communication Ab-
normality
Please restart to see if the error disappears,
if not, please contact your dear for help.
E30
Throttle position sensor
failure, should recalibrate
the throttle position sen-
sor.
Please refer to section
6.3.2 Recalibration
to
recalibrate the throttle position sensor.
E56
Communication Error bet-
ween outboard and battery
Check if the communication cable between
outboard and battery is well connected, if
yes, please restart the system.
E60
The remote control is run-
ning out of power.
Please connect the remote control to the
pod by a communication cable. Please refer
to section
6.2.2 Charged by Wired Connecti-
on
.
All cha-
racters
display
The motor has no power.
Connect the battery to the outboard and
then turn on the main switch.
Not paired
Please refer to section
6.6
Pairing Control
System with the Outboard.
If the problem persists, please consult your ePropulsion authorized dealer for
assistance.