![ePropulsion SPIRIT 1.0 Evo User Manual Download Page 37](http://html.mh-extra.com/html/epropulsion/spirit-1-0-evo/spirit-1-0-evo_user-manual_2418403037.webp)
35
6.3.2 Recalibration
If the error code displays as the figure
6-7, users should calibrate the throttle
strictly
as below steps.
Figure 6-7
Recalibration process
LCD Displaying
Step1: Long press “
^
” button for 10s until “CAL FO”
displays.
Step2: Push the throttle to the maximum forward power
position, then press "
" button. “CAL ST” will display
and “CAL” will be blinking.
Step3: Pull the throttle to the middle (zero) position whe-
re you can hear a click sound, then press "
"button,
“CAL bA” will display and “CAL” will be blinking.
Step4: Pull the throttle to the maximum backward power
position, then press "
" button. “CAL FO” will display
and calibration is completed. A blinking “RESET” will dis
-