37
Code
Cause
Solution
E57
NAVY battery
overcurrent
1. Ensure the paralleled NAVY batteries
have similar voltage with pressure
difference within 2V.
2. Ensure the power cable and battery
are firmly connected to avoid poor
contact.
3. Restart the battery when the error
occurs and keep the parallel state for 30
minutes to wait for the batteries to self-
balance the voltage.
4. If the error occurs, users can also
continue operating after restarting the
battery, but do not operate at full power
state. The operating power is suggested
to be lower than two thirds of full power.
Please fully charge the battery after use.
E60
The Remote
Control/Tiller is
running out of
power.
Please connect the Remote Control/Tiller
to the outboard by a communication
cable. Please refer to section
5.2.2
Charged by Wired Connection
All
characters
display
The motor has no
power.
Connect the battery to the outboard and
then turn on the main switch.
Device addresses
mismatch.
Please refer to section 5.4
Pairing
Remote Control/Tiller with the Outboard
Motor
and pair the Remote Control/Tiller
with the outboard motor again.
Buzzer
beeps
Normal
The buzzer beeps when the remaining
battery drops to 50%, 20% and 10%.
If the problem persists, please consult your ePropulsion authorized
dealer for assistance.