background image

page | 2

ATTENTION !   RISQUE DE CHOC ! ÉLECTRIQUE PAS OUVRIR !

CAUTION

Risk of Electrical Shock!

DO NOT OPEN!

!

 

The lightning flash with arrowhead symbol, within an equilateral triangle, is intended 

to alert the user to the presence of uninsulated dangerous voltage within the product’s 

enclosure that may be of sufficient magnitude to constitute a risk of electric shock to 

persons.

The exclamation point within an equilateral triangle is intended to alert the user to 

the presence of important operating and maintenance (servicing) instructions in the 

literature accompanying the appliance.

!

!

A. 

Read these instructions.

B. 

Keep these instructions.

C. 

Heed all warnings.

D. 

Follow all instructions.

E. 

Do not use this apparatus near water.

F. 

Clean only with dry cloth.

G. 

Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions.

H. 

Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including 

amplifiers) that produce heat.

I. 

Do not defeat the safety purpose of the polarized or grounding type plug. A polarized plug has two blades 

with one wider than the other. A grounding type plug has two blades and a third grounding prong. The 

wide bladed or the third prong are provided for your safety. If the provided plug does not fit into your outlet, 

consult an electrician for replacement of the obsolete outlet.

J. 

Protect the power cord from being walked on or pinched particularly at plugs, convenience receptacles, and 

the point where they exit from the apparatus.

K. 

Only use attachments/accessories specified by the manufacturer.

L. 

Use only with the cart, stand, tripod, bracket, or table specified by the manufacturer, or sold with the 

apparatus. When a cart is used, use caution when moving the cart/apparatus combination to avoid 

injury from tip-over.

M. 

Unplug this apparatus during lightning storms or when unused for long periods of time.

N. 

Refer all servicing to qualified service personnel. Servicing is required when the apparatus has been 

damaged in any way, such as power-supply cord or plug is damaged, liquid has been spilled or objects have 

fallen into the apparatus, the apparatus has been exposed to rain or moisture, does not operate normally, or 

has been dropped.

O. 

The equipment shall be used at maximum 45 degree C ambient temperature.

P. 

To reduce the risk of electrical shock, do not open the equipment. For safety reasons it is only allow to the 

opened by qualified service personnel.

Q.  WARNING:

 To reduce the risk of fire or electric shock, do not expose this apparatus to rain or moisture. 

Additionally, the apparatus shall not be exposed to dripping or splashing and no objects filled with liquids 

shall be placed on the apparatus.

R. 

The mains plug is used as the disconnect device and shall remain readily operable.

S. 

The product shall be used on open bench.

T. 

No naked flame sources, such as lighted candles, should be placed on the apparatus.

U. 

The apparatus should be connected to a mains socket outlet with a protective earthing connection.

V. 

Ventilation should not be impeded by covering the ventilation openings with items, such as newspapers, 

table-cloths, curtains, etc.

W. 

This apparatus is suitable for use in tropical climates.

Summary of Contents for EA-AMP-SUB-1D-500R

Page 1: ...EA AMP SUB 1D 500R INSTALLATION MANUAL EA AMP SUB 1D 500R ...

Page 2: ...exit from the apparatus K Only use attachments accessories specified by the manufacturer L Use only with the cart stand tripod bracket or table specified by the manufacturer or sold with the apparatus When a cart is used use caution when moving the cart apparatus combination to avoid injury from tip over M Unplug this apparatus during lightning storms or when unused for long periods of time N Refe...

Page 3: ...e RCA input to the left and right front output connections on a receiver or pre amp processor E RCA LINE LEVEL OUTPUTS OUT Connects additional amplifiers F 12V TRIGGER IN OUT 12V TRIGGER IN Turns on the amp when a 12V signal is received from another 12V trigger device 12V TRIGGER OUT Sends a 12V signal to another 12V trigger device G IR PORT Connects IR device H MINI USB PORT Reserved for future u...

Page 4: ...eaching the last option in the funtion sub menu press to exit to the main menu NOTE The sub menu will scroll continuously in both directions until the knob is pressed to exit once reaching the Menu Exit screen A CROSSOVER 40Hz 250Hz LFE Selects the low pass filter for the amplifier NOTE Set LFE when using the LPF on an AVR DEFAULT LFE B SPEAKER EQ FLAT DUAL8 BSUB12 HSUB10 Selects the EQ mode for t...

Page 5: ...anges in settings Press and hold knob for 10 seconds to unlock ON Locks controls OFF Allows adjustment of settings DEFAULT OFF I FACTORY RESET Resets all functions to default settings Push the knob to enter the reset menu turn the knob once to select firmware reset then push once more to reset to factory settings NOTE Firmware version is displayed on screen when selected J MENU EXIT SCREEN Press t...

Page 6: ...ould be allowed above and below the amplifier for optimum performance EA AMP S UB 1D 50 0 Installation Attach ears to the amplifier if mounting into rack Bottom feet on the amplifier chassis may be removed if necessary Minimum of 5 of free air space above and below Minimum of 5 of free air space above and below Minimum of 2 of depth behind unit to accommodate cables and connectors Minimum of 3 fre...

Page 7: ... of each subwoofer should not be less than 8Ω LS RS SUB CEN L R Switched Outlet 12V Trigger Out IN R L LFE OUT OUT IN IR UPDATE OPERATE TRIGGER DC 12V EA AMP SUB 1D 500R SUB 1 SUB 2 Total Impedance Sub 1 Sub 2 Minimum 4Ω 100 120V AC 220 240V AC FUSE T8AL 250V 100 120V 60Hz 220 240V 50Hz 500WATTS Designed and Engineered in USA Made in China IN R L LFE OUT OUT IN IR UPDATE OPERATE TRIGGER DC 12V EA ...

Page 8: ...RS SUB CEN LF RF Switched Outlet 12V Trigger Out IN R L LFE OUT OUT IN IR UPDATE OPERATE TRIGGER DC 12V If the receiver does not have a 12V trigger output using a 12V power supply plugged into a switched outlet on the receiver provides the same functionality Connect the appropriate conductor to each screw terminal observing correct polarity 12V DC Tip GND Sleeve ...

Page 9: ...UPDATE OPERATE TRIGGER DC 12V IN R L LFE OUT OUT IN IR UPDATE OPERATE TRIGGER DC 12V 3 5mm Mono Mini 3 5mm Mono Mini AV Receiver AV Receiver IR Receiver IR Receiver IR Repeater Control System Power Cord Power Cord EA AMP SUB 1D 500R EA AMP SUB 1D 500R IR Repeater Connections Control System Connections 2015 Episode ...

Page 10: ...e lower frequencies Experiment with different frequency settings until finding one that sounds best When using the LFE input set to LFE and make any crossover adjustments in the preamplifier or receiver crossover settings DUAL8 Optimized for use with Dual 8 In Wall Subwoofer Setting Use Case Value Initial Volume 1 ES SUB IW DUAL8 53 2 ES SUB IW DUAL8 50 Crossover LFE Initial Phase 0 NOTE AVR bass ...

Page 11: ...o function trouble free Most problems that occur are due to simple issues If having trouble check the list of simple fixes below If the problem persists contact Episode technical support at 866 838 5052 No audio output Audio cable to the source component is not connected properly connection to output or the cable is defective Check connections or replace cable with one that has been verified as go...

Page 12: ...kmanship under normal conditions of use This warranty shall not apply to products that have been abused modified or disassembled Products to be repaired under this warranty must be returned to a designated service center with an assigned return authorization RA number Contact technical support at support episodeaudio com for an RA number CONTACTING TECHNICAL SUPPORT 866 838 5052 support episodeaud...

Reviews: