![Epilog Laser Zing 24 Quick Start Manual Download Page 6](http://html.mh-extra.com/html/epilog-laser/zing-24/zing-24_quick-start-manual_2417766006.webp)
ZING 24 ALIGNMENT
ode and CO2 laser to the center of the
alignment target using the adjustment
screws on mirror #2.
1. Locate mirror #2 located at the top of
the laser periscope, shown below.
2. Adjustments of this mirror are made
using the three (3) 3/32” allen head screws,
each of which move the laser/red dot
in a different direction on the target.
The movement each screw controls are
shown below:
3. Locate the red dot diode at the front of
the laser tube, shown below:
4.
Adjustments of the red dot diode are
made using the three (3) 3/32” allen head
screws, each of which move the red dot
in a different direction on the target.
The movement each screw controls are
shown below:
NOTE: Small adjustments can make a big
difference in laser location. To avoid “loss”
of the laser and red dot fire, use very
small adjustments when attempting to
center the burn mark. If at any point you
are unable to get a burn mark or see the
red dot diode, call Epilog Tech Support.