Parameters
Default
Range
Settings on XDS1 module
Settings on XDS2 module
SYS
12VDC
12/24/36
/48VDC
1) Under the "USE" battery type, press the
button
to enter the “SYS” interface.
2) Press the
button again to display the current
“SYS” value.
3) Press the
button to modify the parameter.
4) Press the
button to confirm and enter the next
parameter.
1) Under the "USE" battery type, press the
button
to enter the “SYS” interface.
2) Press the
button again to display the current
“SYS” value.
3) Press the
or
button to modify the
parameter.
4) Press the
button to confirm and enter the next
parameter.
BCV
14.4V
9~17V
5) Press the
button again to display the current
voltage value.
6) Press the
button to modify the parameter(short
press to increase 0.1V, long press to decrease
0.1V).
7) Press the
button to confirm and enter the next
parameter.
5) Press the
button again to display the current
voltage value.
6) Press the
or
button to modify the parameter
(press
button to increase 0.1V, press
button to decrease 0.1V).
7) Press the
button to confirm and enter the next
parameter.
FCV
13.8V
9~17V
LVR
12.6V
9~17V
LVD
11.1V
9~17V
LEN
NO
YES/NO
Press the
button to modify the switch status.
Note: It exists automatically from the current interface
Press the
or
button to modify the switch
status.