13
CAUTION
common-positive equipment are used, and the positive electrode is grounded,
the controller may be damaged.
Step 4
:
Connect
accessories
Connect the remote temperature sensor cable
(
Model:RT-MF58R47K3.81A
)
(
Model:RTS300R47K3.81A
)
Connect the remote temperature sensor cable to the interface
①
and place the other end close to
the battery.
CAUTION
If the remote temperature sensor is not connected to the controller, the default
setting for battery charging or discharging temperature is 25 °C without
temperature compensation.
Connect the accessories for RS485 communication
Refer to chaper4
“Control Parameters Setting”.
Step 5
:
Powered on the controller
Closing the battery fuse will switch on the controller. Then check the status of the battery indicator
(the controller is operating normally when the indicator is lit in green). Close the fuse and circuit
breaker of the load and PV array. Then the system will be operating in the preprogrammed mode.
CAUTION
If the controller is not operating properly or the battery indicator on the controller
shows an abnormality, please refer to 5.2 “Troubleshooting”.
Temperature Sensor
Remote Temperature Sensor
Cable (Optional)