background image

 

MPPT Solar Charge Controller

 

 

User Manual

 

Models: 

XTRA1206N/XTRA2206N 

XTRA1210N/XTRA2210N 

XTRA3210N/XTRA4210N

 

XTRA3215N/XTRA4215N 

XTRA3415N/XTRA4415N

 

 

Summary of Contents for XTRA Series

Page 1: ...MPPT Solar Charge Controller User Manual Models XTRA1206N XTRA2206N XTRA1210N XTRA2210N XTRA3210N XTRA4210N XTRA3215N XTRA4215N XTRA3415N XTRA4415N...

Page 2: ......

Page 3: ...eable components exist inside the controller DO NOT disassemble or attempt to repair the controller Mount the controller indoors Avoid exposure to the components and do not allow water to enter the co...

Page 4: ......

Page 5: ...quirements 5 2 3 Wire Size 7 2 4 Mounting 9 3 Display units 12 3 1 Basic Display unit XDB1 12 3 2 Standard Display unit XDS1 13 3 3 Adanced Display unit XDS2 17 4 Parameters Setting 22 4 1 Battery par...

Page 6: ...5 Others 33 5 1 Protection 33 5 2 Troubleshooting 35 5 3 Maintenance 37 6 Technical Specifications 38 Annex I Conversion Efficiency Curves 42...

Page 7: ...the battery s lifespan and significantly improve the system performance Comprehensive electronic protection of overcharge over discharge PV battery reverse polarity etc ensures the solar system is mor...

Page 8: ...with 5V 200mA protected output for no power devices with Modbus protocol Support monitoring and setting the parameters via the APP or PC software IP33 Ingress protection XTRA4415N 48V system For the B...

Page 9: ...2VDC 2 12 24VDC Max PV open circuit voltage 10 100V 15 150V Common Negative System 1 4 Product Classification Classify Model Picture Display Basics XTRA N XDB1 LED Indicators PV battery working status...

Page 10: ...orking status Buttons View or set the parameters or clear the error information LCD PV display voltage current generated energy power Battery display voltage current temperature capacity Load display...

Page 11: ...urrounding materials or even cause a fire Ensure tight connections use cable clamps to secure cables and prevent them from swaying in mobile applications The controller can work with lead acid and lit...

Page 12: ...nditions STC Standard Test Condition Irradiance 1000W m2 Module Temperature 25 Air Mass1 5 XTRA1210 2210 3210 4210N System voltage 36 cell Voc 23V 48 cell Voc 31V 54 cell Voc 34V 60 cell Voc 38V Max B...

Page 13: ...lues are calculated under standard test conditions STC Standard Test Condition Irradiance 1000W m2 Module Temperature 25 Air Mass1 5 2 3 Wire Size The wiring and installation methods must conform to n...

Page 14: ...15N at 25 environment temperature Battery and Load Wire Size The battery and load wire size must conform to the rated current The reference size is as below Model Rated charge current Rated discharge...

Page 15: ...The controller requires at least 150mm of clearance above and below for proper airflow Ventilation is highly recommended if mounted in an enclosure Installation Procedure Figure 2 1 Mounting Step 1 D...

Page 16: ...or an unattended area In that case it must install an external surge arrester Suppose an inverter is to be connected to the system In that case you must connect the inverter directly to the battery no...

Page 17: ...ng or discharging temperature setting is 25 C without temperature compensation Connect the accessories for RS485 communication Refer to chaper4 Control Parameters Setting Step 5 Powered on the control...

Page 18: ...n On Solid Normal Green Slowly flashing 1Hz Full Green Fast flashing 4Hz Over voltage Orange On Solid Under voltage Red On Solid Over discharged Red Slowly Flashing 1Hz Battery Overheating Lithium bat...

Page 19: ...0 Indicator is OFF Indicator is on Solid Indicator is slowly flashing Load status Battery Capacity Level Green on solid The load is ON Green OFF The load is OFF 3 Button In the manual mode it can cont...

Page 20: ...r no operation for 10s It will exit the setting interface automatically 3 Interface Note The display screen can be viewed clearly when the angle between the end users horizontal sight and the display...

Page 21: ...sumed energy Load working mode Timer1 Load working mode Timer2 4 Setting Clear the generated energy Operation Step 1 Long press the button under the generated energy interface and the value will flash...

Page 22: ...peration Step1 Press the button to jump to the battery voltage interface Step2 Long press the button until the battery type interface flashes Step3 Press the button to change the battery type Step4 Pr...

Page 23: ...dicator Indicator Color Status Instruction Green On Solid PV charges the battery with a low current Green OFF 1 No sunlight 2 Connection error 3 Low PV voltage Green Slowly Flashing 1Hz Normal chargin...

Page 24: ...e battery capacity level and temperature unit Press the button Controller load browsing interface Setting data Press the button and hold 5s Setting the load working mode Press the button Enter into se...

Page 25: ...erated Energy 2 Battery parameters Display Voltage Current Temperature Battery capacity level 3 Load parameters Display Voltage Current Power Consumed energy Load working mode Timer1 Load working mode...

Page 26: ...ress the button twice or wait for 10S of no operation to automatically go back to the battery parameters setting interface CAUTION Please refer to chapter 4 1 for the battery control voltage setting w...

Page 27: ...Operation Step 1 Press the button to browse the PV parameters on the initial interface Then press the button to enter the PV parameters setting interface Step 2 Long press the button to enter the LCD...

Page 28: ...he default battery type is selected the battery voltage parameters cannot be modified To change these parameters select the USE type Step1 Enter the USE battery type Detailed operations of entering th...

Page 29: ...0S of no operation to automatically go back to the battery parameters setting interface 3 Long press the button to enter the battery type interface again on the battery parameters setting interface 4...

Page 30: ...crease 0 1V 7 Press the button to confirm and enter the next parameter Float charging voltage FCV 13 8V 9 17V Low voltage reconnect voltage LVR 12 6V 9 17V Low voltage disconnect voltage LVD 11 1V 9 1...

Page 31: ...BCV 0 6V voltage level BCV 0 1V voltage level BCV 0 1V voltage level Over voltage reconnect voltage BCV 0 6V voltage level BCV 0 1V voltage level Boost charging voltage Equalize charging voltage BCV...

Page 32: ...Bluetooth module by Bluetooth signal When selecting the battery type as USE set the voltage parameters by the APP Refer to the cloud APP manual for details 3 Controller parameters Battery voltage para...

Page 33: ...rging Limit Voltage Equalize Charging Voltage Boost Charging Voltage Float Charging Voltage Boost Reconnect Charging Voltage B Over Voltage Disconnect Voltage Over Voltage Reconnect Voltage C Low Volt...

Page 34: ...be x2 for LFP8S and x4 for LFP15S LFP16S Battery type Battery parameters LNCM LNCM3S LNCM6S LNCM7S LNCM13S LNCM14S User Over voltage disconnect voltage 12 8 V 25 6 V 29 8 V 55 4V 59 7V 9 17V Charging...

Page 35: ...arging Limit Voltage Equalize Charging Voltage Boost Charging Voltage Float Charging Voltage Boost Reconnect Charging Voltage C Low Voltage Reconnect Voltage Low Voltage Disconnect Voltage Discharging...

Page 36: ...Light ON OFF 2 n Disabled 101 The load will be on for 1 hour after sunset 201 The load will be on for 1 hour before sunrise 102 The load will be on for 2 hours after sunset 202 The load will be on fo...

Page 37: ...software Light ON OFF Light ON Timer Time Control Control the load ON OFF time by setting the real time clock 2 Load mode settings 1 PC setting Connect the controller s RJ45 interface to the PC s USB...

Page 38: ...ough a standard network cable or connect to the Bluetooth module by Bluetooth signal Set the load mode by the APP Refer to the cloud APP manual for details 3 MT50 Setting CAUTION Please refer to the i...

Page 39: ...erate normally after the polarity is corrected CAUTION The controller is damaged when the PV array is connected reversely to the controller and the PV array s actual operating power exceeds 1 5 times...

Page 40: ...cut off the output Suppose the load reconnects the output five times delay of 5s 10s 15s 20s 25s In that case it needs to be cleared by pressing the Load button restarting the controller or switching...

Page 41: ...ay disconnection Charging LED indicator off during daytime when sunshine falls on PV modules properly Confirm that PV wire connections are correct and tight Battery voltage is lower than 8V The wire c...

Page 42: ...BATT indicator fast flashing When the heat sink of the controller exceeds 85 the controller will automatically cut off the input and output circuit When the temperature is below 75 the controller wil...

Page 43: ...eplace some wires if necessary Tighten all the terminals Inspect for loose broken or burnt wire connections Check and confirm that LED is consistent with required Pay attention to any troubleshooting...

Page 44: ...A 20A 10A 20A 30A 40A 30A 40A 30A 40A Battery voltage range 8 32V 8 68V Max PV open circuit voltage 60V 46V 100V 92V 150V 138V MPP voltage range Battery voltage 2V 36V Battery voltage 2V 72V Battery v...

Page 45: ...mpensate coefficient 3mV 2V Default Grounding Common negative RS485 interface 5VDC 200mA RJ45 LCD backlight time Default 60S Range 0 999S 0S the backlight is ON all the time When a lithium battery is...

Page 46: ...aches 81 the reducing charging power mode is turned on Refer to chapter 5 1 Protection 3 protection against solid objects protected against solids objects over 2 5mm 3 protected against sprays to 60 f...

Page 47: ...A4210N 8AWG 10mm2 XTRA3415N 6AWG 16mm2 XTRA4215N 6AWG 16mm2 Weight 0 57kg 0 96kg 1 31kg 1 70kg 2 07kg 2 47kg Certification Safety EN IEC62109 1 UL1741 CSA C22 2 107 1 EMC Emission immunity EN61000 6 3...

Page 48: ...Conversion Efficiency Curves Illumination Intensity 1000W m2 Temp 25 C Model XTRA1206N 1 Solar Module MPP Voltage 17V 34V Nominal System Voltage 12V 2 Solar Module MPP Voltage 34V 45V Nominal System V...

Page 49: ...43 Model XTRA1210N 1 Solar Module MPP Voltage 17V 34V Nominal System Voltage 12V 2 Solar Module MPP Voltage 34V 51V 68V Nominal System Voltage 24V...

Page 50: ...44 Model XTRA2206N 1 Solar Module MPP Voltage 17V 34V Nominal System Voltage 12V 2 Solar Module MPP Voltage 34V 45V Nominal System Voltage 24V...

Page 51: ...45 Model XTRA2210N 1 Solar Module MPP Voltage 17V 34V Nominal System Voltage 12V 2 Solar Module MPP Voltage 34V 51V 68V Nominal System Voltage 24V...

Page 52: ...46 Model XTRA3210N 1 Solar Module MPP Voltage 17V 34V Nominal System Voltage 12V 2 Solar Module MPP Voltage 34V 51V 68V Nominal System Voltage 24V...

Page 53: ...47 Model XTRA4210N 1 Solar Module MPP Voltage 17V 34V Nominal System Voltage 12V 2 Solar Module MPP Voltage 34V 51V 68V Nominal System Voltage 24V...

Page 54: ...48 Model XTRA3215N 1 Solar Module MPP Voltage 17V 34V 68V Nominal System Voltage 12V 2 Solar Module MPP Voltage 34V 68V 102V Nominal System Voltage 24V...

Page 55: ...49 Model XTRA4215N 1 Solar Module MPP Voltage 17V 34V 68V Nominal System Voltage 12V 2 Solar Module MPP Voltage 34V 68V 102V Nominal System Voltage 24V...

Page 56: ...50 Model XTRA3415N 1 Solar Module MPP Voltage 17V 34V 68V Nominal System Voltage 12V 2 Solar Module MPP Voltage 34V 68V 102V Nominal System Voltage 24V...

Page 57: ...51 3 Solar Module MPP Voltage 68V 102V 119V Nominal System Voltage 36V 4 Solar Module MPP Voltage 68V 102V 119V Nominal System Voltage 48V...

Page 58: ...52 Model XTRA4415N 1 Solar Module MPP Voltage 17V 34V 68V Nominal System Voltage 12V 2 Solar Module MPP Voltage 34V 68V 102V Nominal System Voltage 24V...

Page 59: ...53 3 Solar Module MPP Voltage 68V 102V 119V Nominal System Voltage 36V 4 Solar Module MPP Voltage 68V 102V 119V Nominal System Voltage 48V Any changes without prior notice Version number 4 4...

Page 60: ...HUIZHOU EPEVER TECHNOLOGY CO LTD Tel 86 752 3889706 E mail info epever com Website www epever com...

Reviews: