22
Bypass low
voltage
Inverter mode:
Bypass
input voltage
lower than
176VAC
Fault code "BLV"
Buzzer sounds in long cycle
The inverter works normally, AC output
continues.
When the bypass input voltage backs to
normal, the fault warning stops.
Bypass mode:
Bypass
input voltage
lower than
176VAC.
Fault code "BLV"
Buzzer sounds in short cycle
Auto switch to inverter mode, AC output
continues (if the inverter circuit has fault
too, AC output will stop).
When the bypass input voltage backs to
normal, fault warning stops, auto switch
to bypass mode.
Bypass
frequency
abnormal
Inverter mode:
Bypass input frequency exceeds the
50Hz/60Hz±10%
Fault code "BFA"
Buzzer sounds in long cycle
The inverter works normally, AC output
continues.
When the bypass input frequency backs
to normal, the fault warning stops.
Bypass mode:
Bypass input frequency exceeds the
50Hz/60Hz±10%
Fault code "BFA"
Buzzer sounds in short cycle
Auto switch to inverter mode, AC output
continues (if the inverter circuit has fault
too, AC output will stop).
When the bypass input frequency backs
to normal, fault warning stops, auto
switch to bypass mode.
Communication
fault
Fault code "CFA"
AC output continues
Turn on/off the inverter through the
remote switch at the communication
interface.
Summary of Contents for TP10K
Page 1: ...Pure Sine Wave Inverter User Manual Models TP10K TP10KB TP20K TP20KB TP30K TP30KB TP40K TP40KB...
Page 2: ......
Page 12: ...9 1 5 Electrical schematic diagram...
Page 15: ...12 Step3 Takedown the junction box cover plate with special tools Step4 Wiring...
Page 34: ...31 TP30K TP30KB TP40K TP40KB 40KW 26KW 1500M 5000M PO H 0...
Page 36: ...33 Annex 2 Mechanical Dimension Diagram 1 TP10K TP10KB...
Page 37: ...34 2 TP20K TP20KB...
Page 38: ...35 3 TP30K TP30KB...
Page 39: ...36 4 TP40K TP40KB Any changes without prior notice Version number V2 1...