background image

 

29 

 
 

Item 

IP3000-12-Plus(T) 

Output continuous 
power 

3000W@35

@ Rated input voltage 

Surge power 

6000W@5S 

Output voltage 

220VAC(±3%)

230VAC(-7%~+3%) 

Output frequency 

50/60Hz±0.2% 

Output wave 

Pure Sine Wave 

Output distortion THD 

THD≤3%(Resistive load) 

Load power factor 

0.2~1(VA 

≤ Continuous output power) 

Rated input voltage 

12VDC 

Input voltage range 

10.8

16VDC 

Rated output power 
efficiency

 

87% 

Max. efficiency

 

94%(30% load) 

Self-consumption 

0.2A 

No-load current 

1.6A 

USB output 

5VDC/Max.1A 

RS485 com. port 

5VDC/200mA 

Environmental parameters 

Input terminal 

M10 

Overall dimension 
(L*W*H) 

557×231.5×123mm 

Mounting dimension 

532×145mm 

Mounting hole size 

Φ

6mm 

Weight 

10.5kg 

Load  power  is  continuous  output  power  when  the  DC  input  is  the  rated  voltage 

(25

℃)

 

This efficiency  is referred  to  the  max.  power when  connected  with  different load 

under the rated DC input voltage. 

Summary of Contents for IP1500-12-Plus(T)

Page 1: ...1 Models IP1500 Plus IP2000 Plus IP3000 Plus PURE SINE WAVE INVERTER USER MANUAL...

Page 2: ......

Page 3: ...2 5 1 LCD 12 5 2 LED indicator and buzzer 12 5 3 Button 13 5 4 Display interface 13 5 5 Setting interface 13 5 6 Fault code 14 6 Installation instructions 15 6 1 General installation notes 15 6 2 Wire...

Page 4: ...ted content carefully WARNING The installation of the system must be done by professional technicians 2 Requirements for technicians Professionally trained TIP Indicates any practical advice for refer...

Page 5: ...me CAUTION Follow the instructions in the manual before placing or moving the inverter CAUTION Make sure there isn t any electrical arcing danger around the operation area before installation CAUTION...

Page 6: ...ments to set the DC input voltage higher or lower may cause the inverter down or even broken CAUTION The cable between battery and inverter should be less than 3meters otherwise please reduce the curr...

Page 7: ...cause electric shock Touch the wiring copper row terminals or internal devices which may cause electric shock The power cable connection is loose Screw or other components inadvertently falls into the...

Page 8: ...verter without voltage or current During installation and maintenance please post temporary warning signs or put up roadblocks to prevent unrelated people from entering the area Improper maintenance o...

Page 9: ...ple areas where need DC to AC such as solar AC power system vehicle system RV power supply security monitoring system emergency lighting system field power system household power system etc The invert...

Page 10: ...ly LCD design to simply monitor and parameter configure Supports phone Apps and PC software remote control Output voltage 220 230VAC and frequency 50 60Hz optional USB ports to power DC fans and other...

Page 11: ...Max 1A Ventilation fan External switch connection point LCD Inverter switch AC output terminal Grounding terminal Ventilation fan 1 The cooling fan will automatically turn on if the inverter could rea...

Page 12: ...the inverter reaches all the conditions as below Heat sink temperature is lower than40 The Internal temperature is lower than 40 The output power is lower than 40 of the rated power The products of th...

Page 13: ...10 3 Designations of models...

Page 14: ...12 Plus CAUTION Suggest that the DC input terminal of the inverter directly connects to the battery DO NOT connect to the battery terminal of the charge source Otherwise the charging voltage spikes o...

Page 15: ...tor Fault indicator Buzzer Status Blue on solid Red off Buzzer no sounds Output is normal Blue slowly flashing 1 4Hz Red off Buzzer sounds Input under voltage Blue fast flashing 1Hz Red off Buzzer sou...

Page 16: ...button and hold on 2s The output is ON OFF Default ON Enter the setting interface Press the button Exit the parameter s setting interface at the setting interface Press the button and hold on 2s Clea...

Page 17: ...voltage reconnect voltage 12 5V 12 0V 13 0V step size 0 1V Over voltage reconnect voltage 14 5V 14 0V 15 0V step size 0 1V Over voltage disconnect voltage 16V 15 5V 16 2V step size 0 1V The inverter...

Page 18: ...nect the DC input even though the inverter has a high range of DC input voltages Too high or too low may cause the inverter to stop working even damage the inverter Surge voltage less than 20V for 12V...

Page 19: ...re size Breaker IP1500 12 Plus T 1 5mm 2 15AWG AC 2P 10A IP2000 12 Plus T 2 5mm 2 13AWG AC 2P 16A IP2000 22 Plus T 2 5mm 2 13AWG AC 2P 16A IP2000 42 Plus T 2 5mm 2 13AWG AC 2P 16A IP3000 12 Plus T 4mm...

Page 20: ...ling through case if installed in a closed box IP1500 12 Plus IP2000 Plus IP3000 12 Plus Step3 Wiring WARNING The AC equipment shall be determined by the continuous output power of the inverter but th...

Page 21: ...rrent of the inverter it must be installed on the battery side with a distance from the battery not greater than 150mm Wiring order Ground IP1500 12 IP2000 Plus IP3000 12 Plus Battery IP1500 12 IP2000...

Page 22: ...he related hole Cut off the power and use a sharp tool to insert it into the small hole on the top of the wire before removing the wire 2 Connect AC load IP1500 12 IP2000 Plus IP3000 12 Plus Accessori...

Page 23: ...h on the input breaker or the fuse between inverter and battery Turn on the power switch to start the inverter blue indicator on solid and the AC output is normal Turn on the load one by one and check...

Page 24: ...cent lamp If the fault indicator is red and the buzzer alarms when turn on the inverter please switch off the loads and inverter immediately Refer to chapter 7 Troubleshooting After troubleshooting pl...

Page 25: ...e indicator fast flashing Buzzer sounds LCD display IP 2 Plus Ui 32 2V IP 4 Plus Ui 64 4V WARNING The inverter has the input over voltage protection but the surge voltage less than 20V for 12V system...

Page 26: ...indicator slowly flashing LCD display S 1 8Pe S Output power Pe Rated power The output is OFF after the10s Buzzer sounds Red indicator slowly flashing LCD display S 2Pe Input rated voltage S Output p...

Page 27: ...times attempt until restarting the inverter 6 Overtemperature Protection Phenomenon Instruction LCD display Inverter turns OFF The heat sink or internal temperature is higher than some value Inverter...

Page 28: ...Measure the DC input voltage if the voltage is lower than16 32 64V Adjust the input voltage to recover normally Red indicator slowly flashing Buzzer sounds LCD display Overload Reduce the number of th...

Page 29: ...ny troubleshooting or error indication Take corrective action if necessary Confirm that all the terminals have no corrosion insulation damaged high temperature or burnt discolored sign tighten termina...

Page 30: ...12VDC Input voltage range 10 8 16VDC Rated output power efficiency 89 Max efficiency 93 30 load Self consumption 0 2A No load current 1 4A 12V USB output 5VDC Max 1A RS485 com port 5VDC 200mA Environ...

Page 31: ...C 21 6 32VDC 43 2 64VDC Rated output power efficiency 88 91 92 5 Max efficiency 94 30 load 93 30 load 94 5 30 load Self consumption 0 2A 0 2A 0 2A No load current 1 2A 1 0A 0 5A USB output 5VDC Max 1A...

Page 32: ...oltage range 10 8 16VDC Rated output power efficiency 87 Max efficiency 94 30 load Self consumption 0 2A No load current 1 6A USB output 5VDC Max 1A RS485 com port 5VDC 200mA Environmental parameters...

Page 33: ...parameters Working Temperature 20 50 Refer to the Reduced capacity curve Storage Temperature 35 70 Humidity 95 N C Enclosure IP20 Altitude 5000m Derating to operate according to IEC62040 at a height...

Page 34: ...attery voltage exceeds the input voltage limit of the inverter Damage caused by the working environment temperature exceeds the rated range Unauthorized dismantling the inverter or attempted repair to...

Page 35: ......

Page 36: ...HUIZHOU EPEVER TECHNOLOGY CO LTD Beijing Tel 86 10 82894896 82894112 Huizhou Tel 86 752 3889706 E mail info epsolarpv com Website www epsolarpv com www epever com...

Reviews: