![Epever ET4415BND User Manual Download Page 14](http://html1.mh-extra.com/html/epever/et4415bnd/et4415bnd_user-manual_2417289014.webp)
10
point voltage (V
mpp
) of the MPPT controller, the series number of different types
PV modules can be calculated. The below table is for reference only.
ET4415BND/ET6415BND
:
System
voltage
36cell
Voc
<
23V
48cell
Voc
<
31V
54cell
Voc
<
34V
60cell
Voc
<
38V
MAX.
Best
MAX.
Best
MAX.
Best
MAX.
Best
12V
4
2
2
1
2
1
2
1
24V
6
3
4
2
4
2
3
2
48V
6
5
4
3
4
3
3
3
System
voltage
72cell Voc
<
46V
96cell Voc
<
62V
Thin-Film
Module
Voc
>
80V
MAX.
Best
MAX.
Best
12V
2
1
1
1
1
24V
3
2
2
1
1
48V
3
2
2
2
1
NOTE
: The above parameter values are calculated under standard test
conditions (STC (Standard Test Condition)
:
Irradiance 1000W/m
2
,
Module
Temperature 25
℃,
Air Mass1.5.)
ET6420BND
:
System
voltage
36cell
Voc
<
23V
48cell
Voc
<
31V
54cell
Voc
<
34V
60cell
Voc
<
38V
MAX.
Best
MAX.
Best
MAX.
Best
MAX.
Best
12V
4
2
2
1
2
1
2
1
24V
6
3
4
2
4
2
3
2
48V
8
5
5
4
5
3
4
3
System
voltage
72cell Voc
<
46V
96cell Voc
<
62V
Thin-Film
Module
Voc
>
80V
MAX.
Best
MAX.
Best
12V
2
1
1
1
1
24V
3
2
2
1
1
48V
4
3
2
2
2
NOTE
: The above parameter values are calculated under standard test
conditions (STC (Standard Test Condition)
:
Irradiance 1000W/m
2
,
Module
Temperature 25
℃,
Air Mass1.5.)