EP Lighting EP-UVAW-20 User Manual Download Page 6

Product 

M

aintenance

Common failure

Possible cause

Troubleshooting

The unit is not 

working

The purification 

effect is poor

Power cord is not plugged, or 

power has no electricity

If above corrective actions are not able to solve the problem, please contact sales and after-sales 

service assigned by our company. For safety, please do not disassemble the unit and maintain by 

yourself to avoid damage.

Please follow the following instructions for the safety of personnel, equipment and the other electrical loads in the 

system. Failure to do so may result in the damage of the equipment and harm to the personnel operating the unit, and 

warranty void.

Do not plug or unplug the power by wet hands to avoid electric shock. Unplug the power while moving the purifier.

It is prohibited to use the device in moist area such as bathroom to avoid shock and accelerated aging of electrical 

system.

The air purifying sterilizer is not designed for filtering kitchen smoke near around kitchen exhaust.

High-

voltage

 negative ion module is contained inside of the device, do not repair or disassemble.

Please do not cover the air inlet and outlet

 that

 prevent the 

efficient purification of the air.

It is prohibited to touch air inlet metal part and insert any foreign matter in air outlet, to avoid equipment malfunction.

In case any damage on the appearance or interior, or any abnormal noise, peculiar smell, smog, please cut off the 

power in a safe way, and contact the EPL promptly. Please do not disassemble the product.

If the equipped power plug does not match with user socket, or damage occurs to the power cord, please contact the 

EPL to change or allocate new parts. Please do not change the power cord

 without EPL approval.

R

emove the plug if the product is not in use for a long time.

This product is not able to eliminate carbon monoxide or radon, thus, in case any fire or chemical disaster, it can not 

be used as security liability or replacement option or ventilate equipment.

While replacing the filter or cleaning the inter

n

al parts, please turn off the power by On/Off button on the control panel 

then remove the plug.

Safety Instructions

Plug in the power supply

Air output is low

Abnormal noise 

from the unit 

Power switch is not ON

Press ON/OFF button

Change the filter

End of service life

Air inlet/outlet is blocked 

Wrong installation of the filter direction

The filter is too dirty

Change the filter

Install the filter in correct direction

Clear the inlet/outlet passages

Make sure all the plastic packaging is removed / check any damage on the 

appearance before the operation

Make sure air inlet and outlet is not blocked by other 

objects

, clean it if any

While turning on the negative ion function, "fizz" sounds is normal

Summary of Contents for EP-UVAW-20

Page 1: ...SenseTM for air quality detection and automatic sterilization control Six layers of sterilization Pre Cotton HEPA Activated Carbon UVC TiO2 UVA Negative Ions Quite running double fans to cover 10 22...

Page 2: ...igh temperature high humidity excessive dust corrosive flammable and combustible gas such as kitchen and bathroom Do not use the device around heating equipments such as oven fan heater or other heati...

Page 3: ...utes to warm up after the machine starts during which the air quality indicator is not bright After 2 minutes of warm up the air quality indicator automatically detects the air quality and turns ON ap...

Page 4: ...ended to use the fragrance Warning Disassembly Please make sure the power plug is pulled out before disassembling the product Tip while disassembling the product could be laid againt the wall or other...

Page 5: ...be cleaned by soft brush every half month to clear away the large pollutant like hairs Waring Do not flush or soak the filter in water or any other liquid detergents Pre Cotton filter High Efficiency...

Page 6: ...n air outlet to avoid equipment malfunction In case any damage on the appearance or interior or any abnormal noise peculiar smell smog please cut off the power in a safe way and contact the EPL prompt...

Page 7: ...g surges earthquake fire flood and some other natural disasters Damage caused by maintenance technician who are not assigned by EP Lighting Damage caused by violation of operating requirements noted i...

Page 8: ...EP Lighting Inc Please visit our websites eplightinc com uvkleen us ep2000 com...

Reviews: