background image

12

13

 

60 

Spring washer 6 

88 

Safety rod 

61 

Nut M6 

89 

Bushing 

62 

Nut M8 

90 

Screw M10×40 

63 

Spring washer 8 

91 

External scissors for chassis 

64 

Washer 

92 

Bushing 

65 

Spring washer 12 

93 

Roller for chassis 

66 

Hex screw M12×30 

94 

Washing 

67 

Screw M10×25 

16 

95 

Bushing 

68 

Front wheel 

96 

Pin axle 

69 

Nut M10 

16 

97 

Pin axle for chassis 

70 

Front wheel 

98 

Pin axle for chassis 

71 

Chassis 

99 

Pin axle for table 

72 

Screw M6x8 

100 

Bushing 

73 

Table 

101 

Screw M6×16 

74 

Roller for table 

102 

Cable 

75 

Bushing 

103 

Cable velcro strap 

76 

Retaining ring for axle 20 

  

 

OPERATION INSTRUCTION ENERGY SERVICE-FREE LEAD 

 ACID STORAGE BATTERY

1. Storage and Transportation

Uncharged  ENERGY  storage  battery  needs  no  maintenance,Please  store  it  in  dry  and  frostless 

place.

If  the  density  of  electrolyte  in  filled  battery  is  less  than  1.23kg/l,it  shall  be  recharged  as  soon  as 

possible,If the density of electrolyte filled in is 1.23kg/l,the storage battery shall be recharged when it is 
below 1.18kg/l.

During transportation or storage,the filled storage battery shall be kept upright vertically to prevent 

acid liquid from overflowing.

Cover  opening、 short  circuit、 sliding  and  other  damage  shall  be  avoided  in  the  course  of 

transportation.

2. PUT INTO USE

Precharged but unfilled ENERGY storage battery can be put into use at once without charging after 

electrolyte is filled in it.

When it is being filled,the temperature of battery and electrolyte should be 10℃ at least.

Each unit of battery shall be filled with special acid whose density is 1.28kg/l.(1.23kg/l in the area of 

tropics), and be filled up to the line indicating the maximum level or to the height of
15mm over the top of pole plate.

 Refill proper electrolyte if necessary.

Screw or press the sealing hole tightly.

Clean the acid liquid left on its surface.

The    storage    battery    can    be    in    good    condition    without    any    service    within    5    years    at    the 

temperature of 20℃.

NOTE:  If  the  output  of  the  battery  is  not  enough  due  to  temperature  or  storage,Please  recharge  the 
storage battery.

3. CHARGING

Before recharging,please take the battery down.

The storage battery is allowed to be charged with DC power,Connect the plus pole and minus pole 

of storage battery correspondingly to the poles of the charger.

Ensure to connect the poles rightly,switch on the charger.

When the battery be charged sufficiently,cut off the charger.

Recommended  charging  current  is  1/10  of  battery  capacity(e.g.1/10×44=4.4A  for  the  storage 

battery with capacity of 44Ah.)

In the course of charging,the temperature of electrolyte is not allowed to be above55℃.

If the temperature of electrolyte is above 55℃,stop charging.

If  the  density  of  electrolyte  and  the  voltage  of  the  battery  stop  increasing  for  2  hours,the  storage 

battery could be thought to be charged sufficiently.

When the charging is ended,please check the level of electrolyte,Add pure water to the maximum 

level indicating line if necessary.

4. Maintenance
To ensure the service life of storage battery,the following points must be followed.

Summary of Contents for ETAD35

Page 1: ...e warning caution decal on the unit is lost please contact your local supplier for a new copy Note On this manual WARNING means the danger which can lead death or serious injury CAUTION means the danger which can lead slight injury or property damage Operating Instructions Electric Table Truck BEFORE YOU BEGIN ETAD Series Electric Table Truck ETAD Series Eoslift Warehousing Equipment Corp No 99 Ya...

Page 2: ...9 Parts List Page 1 Page 1 Page 2 Page 2 Page 2 Page 4 Page 4 Page 5 Page 6 1 1 Read the operation manual completely before using and thoroughly understand and follow all safety instructions 2 This lifter is designed to use with stable uniform load on a solid lever floor DO NOT use the lifter for any other purpose than its intended use 3 TRAINED personnel shall operate lifter only OPERATOR shall r...

Page 3: ...eck the smooth movement of the wheels 5 Check the function of brake 6 Check if all the bolts and nuts are tightened firmly DO NOT use lift table if any malfunction or fault is found CAUTION 4 NAME OF PARTS ETAD35 ETAD75 5 Operation Instruction How to use the brake Brake lift table when not moving it in order to prevent sudden movement CAUTION 6 LIFTING UP FORKS CAUTION 1 DO NOT overload lifter Sta...

Page 4: ...xpressed in daily inspection daily 2 Lubricate with grease the guides where roller moves Also lubricate the grease nipples Every month 3 Lubricate all the pivoting points and axles Every 6 months 4 Replace the hydraulic oil for the first time Accumulated working ten hours 5 Replace the hydraulic oil Every 12 months 11 TROUBLE SHOOTING TROUBLE CAUSE REPAIR 1 Faulty wiring 1 Check the wiring referri...

Page 5: ...0 Motor KW 0 7 0 7 Work cycle of hydraulic power pack 3 times of table moving up down per 10 min Approx numbers of lifting at full charge and with full load times 45 40 Approx time required lifting up table Sec 15 15 Wheel mm diameter 150 150 Handle height mm 1180 1180 Weight kg 183 215 6 7 13 HYDRAULIC CIRCUIT WIRING DI AGRAM ACTUAL WI RING DIAGRAM 13 液压回路 接线图 ETAD35 ...

Page 6: ...er Washer 5 Screw M5 10 Screw M5 20 Fuse Spring washer 5 Nut M5 Screw M5 16 Fuse Screw M4 16 Nut M8 Washer 8 Screw M10 16 Spring washer 10 Washer 10 Switch Battery case weldment Covering plate Pad Battery Insulator pad Insulation case Screw M8 40 Battery securing tag Screw M5 16 Roller for table Bushing Retaining ring for axle 20 Internal scissors for table External scissors for table Screw M8 16 ...

Page 7: ...0 16 2 16 Seal ring 14 4 40 Spring washer 10 20 17 High pressure hose 1 41 Washer 10 22 18 Joint 2 42 Switch 1 19 Split Pin 1 43 Battery case weldment 1 20 Covering plate 1 44 Covering plate 1 21 Washer 4 10 45 Pad 1 22 Spring washer 4 10 46 Battery 1 23 Screw M4x10 8 47 Insulator pad 1 24 Battery indicator 1 48 Insulation case 2 49 Screw M8 20 8 77 Internal scissors for table 1 50 Battery securin...

Page 8: ...g filled the temperature of battery and electrolyte should be 10 at least Each unit of battery shall be filled with special acid whose density is 1 28kg l 1 23kg l in the area of tropics and be filled up to the line indicating the maximum level or to the height of 15mm over the top of pole plate Refill proper electrolyte if necessary Screw or press the sealing hole tightly Clean the acid liquid le...

Page 9: ...ase wear protective clothes and guard glasses Do not tilt the storage battery otherwise acid liquid will overflow Emergency Cure when the acid liquid spatters in the eyes wash it with a large quantity of clean water at once then see a doctor Acid liquid on skin and clothes shall be washed with a large quantity of clean water as well If acid liquid is swallowed please see a doctor at once Warning D...

Reviews: