1.Warnings

1. DO NOT allow another person to stand in front of or behind lifter when it starts to move.

2. ALWAYS travel with table in lowered position. Load could fall down.

3. NEVER sit, stand or ride on platform. SEVERE PERSONAL INJURY could result.

4. NEVER go under platform. SEVERE PERSONAL INJURY or DEATH could result.

5. DO NOT use in area of multilevel floor surface that could create loss control and result in

SEVERE INJURY and PROPERTY DAMAGE.

6. DO NOT use lifter on slope, uneven or soft surface. Lifter may become uncontrollable.

SEVERE PERSONAL INJURY and PROPERTY DAMAGE could result.

7. KEEP FEET CLEAR of rolling wheels that could result in SEVERE PERSONAL INJURY.

8. DO NOT load one fork more than the other and DO NOT load tips on table. SEVERE PERSONAL INJURY 

and PROPERTY DAMAGE could result.

9. DO NOT overload lifter. ALWAYS stay within designated capacity and load center rating.

SEVERE PERSONAL INJURY and PROPERTY DAMAGE could result.

10. SHEARING  HAZARD.  NEVER  place  hands  or  feet  under  lowering  table.  SEVERE PERSONAL 

INJURY could result.

11. NO FIRE during charging. Read battery operation manual.

12. HIGH VOLTAGE. Disconnect battery socket before opening control panel box.

13. DO NOT remove battery terminal cover. Short-circuit or electric shock could occur.

2.Cautions

1 Warnings

   

2 Cautions 

   

3 Name of Parts

   

4 Daily Inspection

   

5 Operation Instruction

   

6 Structural Data Form

   

7 Maintenance

   

8 Hydraulic Circuit

   

9 Parts List

   

Page 1

Page 1

Page 2

Page 2

Page 2

Page 4

Page 4

Page 5

Page 6

1

1.    Read  the  operation  manual  completely  before  using  and  thoroughly  understand  and  follow  all  safety 

instructions.

2.   This lifter is designed to use with stable uniform load on a solid lever floor. DO NOT use the lifter for any 

other purpose than its intended use.

3. TRAINED personnel shall operate lifter only. OPERATOR shall read “Operation Manual” completely and 

thoroughly understand the controls and operation of this equipment BEFORE operating the lifter.

4.   ALWAYS observe lifter and ALWAYS stay at the controls while the lifter is in motion, RELEASE controls 

and  STOP  lifter  immediately  if  load  on  lifter  appears  to  become  unstable.  NEVER  leave  the  loaded  lifter 

unattended unless the table is in the fully lowered position and the lifter is locked reliably.

5.   DO NOT slide the load on or off the table. The lift may move allowing the load to fall. SEVERE PERSONAL 

INJURY and PROPERTY DAMAGE could result.

6.      DO  NOT  use  lifter  with  unstable,  unbalanced  or  loosely  stacked  load.  Unbalanced  loads  may  become 

unstable and fall. SEVERE PERSONAL INJURY and PROPERTY DAMAGE could result.

7.   Qualified personnel must perform ALL lifter service only.

8.  ALWAYS  keep  feet,  hands  and  fingers  away  from  casters,  load  wheels  and  all  moving  components. 

SEVERE INJURY could result.

9. ALWAYS perform maintenance and inspections with lifter unloaded.

10. Prolonged continuous working might cause damage of power pack.

11. Stop operation if temperature of hydraulic oil is too high.The lifter is NOT waterproof and is intended to be 

used in a dry environment.

CONTENTS

Summary of Contents for ETAD35

Page 1: ...e warning caution decal on the unit is lost please contact your local supplier for a new copy Note On this manual WARNING means the danger which can lead death or serious injury CAUTION means the danger which can lead slight injury or property damage Operating Instructions Electric Table Truck BEFORE YOU BEGIN ETAD Series Electric Table Truck ETAD Series Eoslift Warehousing Equipment Corp No 99 Ya...

Page 2: ...9 Parts List Page 1 Page 1 Page 2 Page 2 Page 2 Page 4 Page 4 Page 5 Page 6 1 1 Read the operation manual completely before using and thoroughly understand and follow all safety instructions 2 This lifter is designed to use with stable uniform load on a solid lever floor DO NOT use the lifter for any other purpose than its intended use 3 TRAINED personnel shall operate lifter only OPERATOR shall r...

Page 3: ...eck the smooth movement of the wheels 5 Check the function of brake 6 Check if all the bolts and nuts are tightened firmly DO NOT use lift table if any malfunction or fault is found CAUTION 4 NAME OF PARTS ETAD35 ETAD75 5 Operation Instruction How to use the brake Brake lift table when not moving it in order to prevent sudden movement CAUTION 6 LIFTING UP FORKS CAUTION 1 DO NOT overload lifter Sta...

Page 4: ...xpressed in daily inspection daily 2 Lubricate with grease the guides where roller moves Also lubricate the grease nipples Every month 3 Lubricate all the pivoting points and axles Every 6 months 4 Replace the hydraulic oil for the first time Accumulated working ten hours 5 Replace the hydraulic oil Every 12 months 11 TROUBLE SHOOTING TROUBLE CAUSE REPAIR 1 Faulty wiring 1 Check the wiring referri...

Page 5: ...0 Motor KW 0 7 0 7 Work cycle of hydraulic power pack 3 times of table moving up down per 10 min Approx numbers of lifting at full charge and with full load times 45 40 Approx time required lifting up table Sec 15 15 Wheel mm diameter 150 150 Handle height mm 1180 1180 Weight kg 183 215 6 7 13 HYDRAULIC CIRCUIT WIRING DI AGRAM ACTUAL WI RING DIAGRAM 13 液压回路 接线图 ETAD35 ...

Page 6: ...er Washer 5 Screw M5 10 Screw M5 20 Fuse Spring washer 5 Nut M5 Screw M5 16 Fuse Screw M4 16 Nut M8 Washer 8 Screw M10 16 Spring washer 10 Washer 10 Switch Battery case weldment Covering plate Pad Battery Insulator pad Insulation case Screw M8 40 Battery securing tag Screw M5 16 Roller for table Bushing Retaining ring for axle 20 Internal scissors for table External scissors for table Screw M8 16 ...

Page 7: ...0 16 2 16 Seal ring 14 4 40 Spring washer 10 20 17 High pressure hose 1 41 Washer 10 22 18 Joint 2 42 Switch 1 19 Split Pin 1 43 Battery case weldment 1 20 Covering plate 1 44 Covering plate 1 21 Washer 4 10 45 Pad 1 22 Spring washer 4 10 46 Battery 1 23 Screw M4x10 8 47 Insulator pad 1 24 Battery indicator 1 48 Insulation case 2 49 Screw M8 20 8 77 Internal scissors for table 1 50 Battery securin...

Page 8: ...g filled the temperature of battery and electrolyte should be 10 at least Each unit of battery shall be filled with special acid whose density is 1 28kg l 1 23kg l in the area of tropics and be filled up to the line indicating the maximum level or to the height of 15mm over the top of pole plate Refill proper electrolyte if necessary Screw or press the sealing hole tightly Clean the acid liquid le...

Page 9: ...ase wear protective clothes and guard glasses Do not tilt the storage battery otherwise acid liquid will overflow Emergency Cure when the acid liquid spatters in the eyes wash it with a large quantity of clean water at once then see a doctor Acid liquid on skin and clothes shall be washed with a large quantity of clean water as well If acid liquid is swallowed please see a doctor at once Warning D...