8. Power selection
Steamtec II Basic steam generator features adjustable power output, which allows to quickly
set the required power output directly on site and to adjust it later if required.
The power output selection is made by F-fuses (switches) on the main terminal rack of the
steam generator.
Every switch adjusts the power by 3 kW. An 18 kW model allows there-
fore 18 / 15 / 12 / 9 / 6 / 3 kW power output. A 9 kW model allows re-
spectively 9 / 6 / 3 kW power output.
The power reduction can be made by any switch except F1. The upper
switch F1 should always remain “on”. Notice that F2 and F3 switches
have a direct effect on the power in “continuous steam” mode.
The example on the left shows F1- F6 switches of an 18 kW model. The
9 kW version features three switches F1 - F3 respectively.
In order to reduce the power push a switch to the RIGHT. Each switch
equals to 3 kW power capacity. To increase the power again push the
switched off switch to the LEFT into original “on” position.
Factory default setting is the maximum output, all switches are “on”.
Select the power output to match the size and construction of the
steam room. We recommend to prove the power requirement in advance
.
Notice:
please pay attention that the heating elements corresponding to fuses F1 in 9 kW
and F1, F2, F3 in 18 kW model are used for “continuous steam” mode (see chapter “operation”
for details). Switching the F2 and/or F3 fuses off will reduce the power output in “continuous
steam” mode.
Power selection switch of
the Steamtec II 18 kW model
Pic. 9
ON
OFF
F1
F2
F3
F4
F5
F6
ON
ON
OFF
OFF
F1
F2
F3
F1
F2
F3
ON
OFF
F1
F2
F3
F4
F5
F6
Example 1
Example 3
Example 4
Example 2
18 kW power version
18 kW power enabled
9 kW power in continuous
steam mode
9 kW power version
9 kW power enabled
3 kW power in continuous
steam mode
9 kW power version
6 kW power enabled
3 kW power in continuous
steam mode
18 kW power version
12 kW power enabled
3 kW power in continuous
steam mode