Electrical Connection
The electrical connection may only be done
by a certified electrician in compliance with
the guidelines of the local utility company
and the VDE.
Mains connection is carried out using a Schuko
type plug, to be mounted by the customer, to
a separate Schuko type socket with a 16A fuse.
Because of the higher starting current has the
unit to be fused by a 16A circuit breaker with K
characteristic.
All electrical installations and all connection
lines that are installed inside the cabin must
be suitable for an ambient temperature of at
least 170 °C.
Lay the connection cables (max.
5 m
length)
from the separate IR radiators to the relay box
and connect according to the connection dia-
gram.
If more than one IR-radiator is to be connected
per heating circuit, the respective connection
lines fromthese radiators must be connected
in junction boxes provided by the customer
outside the power unit. Only one cable line may
be connected to the terminals of each power
output circuits.
Lay the connection cable from the control ele-
ment to the power switchgear and produce the
plug connections according to the connection
diagram.
Adapting the control to the installed
components.
On the circuit board of the IR control power unit
you will find a pin block for three jumpers
The type of emitters used is set using the jump-
ers 1 + 2.
IR radiant heater
If exclusively IR radiant heaters are
installed, both jumpers remain open
IR heating foil
If IR heating foils are installed, Jump-
er 1 is connected and Jumper 2
remains open.
A radiant heater for the legs can also
be installed
IR radiant heater & IR heating foil
If both IR radiant heaters - except for
the radiant heater for legs - and IR
heating foils are installed, Jumper 2
is connected and Jumper 1 remains
open.
You can set the maximum heating
time with
Jumper 3
Maximum heating time 99 minutes
Jumper 3 open
Maximum heating time 12 hours
Jumper 3 closed
Notice: by connection of IR heating foils the
optional 2nd sensor (surface sensor for heat-
ing foils) shall be connection and activated
through the jumper setting.
Jumper 1
Jumper 2
Jumper 1
Jumper 2
Jumper 3
Jumper 1
Jumper 2
Jumper 1
Jumper 2
Jumper 3
Jumper 3