EOS ECON A2 Installation And User Manual Download Page 13

13

GB

8 Troubleshooting / error messages

Display /
symptom

Cause

Remedy

Interruption or
short circuit in
sensor circuit

Check KTY sensor (approx. 2 kÙ at 20°
C). Check wire (red) and connections for
interruption or short circuit.

Interruption in
limiter circuit

Check continuity on safety temperature
limiter. Check wires (white) and
connections

Unit not working
Display dark

Control unit switch
switched off

Switch on control unit switch

Mains fault

Check on-site fuses and main switch

E

E

power unit

400 V 3 N AC

max .9 kW

L

W

V

N

S

N

L

L

139°C

N

L

L

L

ECON A2

1

2

3

2

3

1

1

U

Connection diagram

Attention!

Dear customer,
according to the valid regulations, the
electrical connection of the sauna heater
and the control box has to be carried
out through the specialist of an
authorized electric shop.
We would like to mention to the fact that
in case of a warrenty claim, you are
kindly requested to present a copy of
the invoice of the executive electric
shop.

Summary of Contents for ECON A2

Page 1: ...1 GB 29343279en 43 06 Installation and user s manual ECON A2 GB IP x4...

Page 2: ...tents 1 General information 1 1 Technical Data 1 2 Package contents 1 3 General safety precautions 2 Assembly of the control unit 2 1 Wall mounting 2 2 Electrical connection 2 2 1 Connecting the sauna...

Page 3: ...assembled correctly l The device may only be used as intended as a control unit for sauna ovens up to 9 kW Up to 36 kW when combined with a breaking capacitor l Completely disconnect the control unit...

Page 4: ...en the wood boards Therefore you have to mount the control unit farther away from the cabin wall so you can lead the cables into the unit In this case use the included spacer tubes as shown in Illust...

Page 5: ...according to the instructions provided by the manufacturer in front of the air intake opening Lead the silicon lines and electrical conduits to their respective terminals on the control unit and conn...

Page 6: ...bins up to 2 x 2m according to Illust 7 and 8 in larger cabins according to Illust s 7 and 9 35 cm 19 cm housing red red sensor board hole sensor housing sauna ceiling center sensor housing on middle...

Page 7: ...ges that follow we would like to familiarise you with the operations and features of your sauna control system In each case the illustrations next to the text show the displays visible on the control...

Page 8: ...1 Finnish sauna operation Press the button to switch on the sauna heater The display alternately shows the current time and the set temperature factory setting 95 C The green operating LED comes on a...

Page 9: ...ched The control range is laid out so that normal temperatures in the bench area can be preselected Press the or button until the set temperature is displayed Press the MODE button The display starts...

Page 10: ...o use the sauna right away Press the button The set temperature is saved the sauna switches on and is regulated to the new set temperature Using the set time function you can select the time that your...

Page 11: ...and hold it down until the newly entered value is permanently displayed Press the MODE button The display starts to flash 17 10 17 10 19 00 To deactivate the preset time press the button This switche...

Page 12: ...er to the first position switch position 0 The unit is now completely switched off 7 The control unit switch The control unit switch can be found on the top end of the unit Using this switch you can i...

Page 13: ...t switch switched off Switch on control unit switch Mains fault Check on site fuses and main switch E E power unit 400 V 3 N AC max 9 kW L W V N S N L L 139 C N L L L ECON A2 1 2 3 2 3 1 1 U 9 Connect...

Page 14: ...ex pressive description of the fault This warrenty covers damaged parts but no defects due to wear and tear In case of complaint please return the equipment in its original packaging or other suitabl...

Reviews: