6 Extended heating time
(commercial use)
In its delivery condition the control unit is
set to a maximum heating period of 6
hours. The heating time limit can be
extended to 12 hours.
To do this, the jumper is plugged in
according to the illustration opposite.
Jumper
For the private sector, the
maximum heating time is 6
hours. Extending this time to 12 hours
is only allowed when operated under
supervision (commercial use).
In case of breakdown, press the control
unit switch on the left part of the rocker to
the first position (switch position 0). The
unit is now completely switched off.
7 The control unit switch
The control unit switch can be found on the
top end of the unit. Using this
switch, you can isolate the electronics from
the mains supply in case of a breakdown.
Please note that operating the control unit
switch returns all settings to the factory
settings.
In order to switch on the light in the sauna
when the unit is switched off, press on the
left part of the rocker to the second position
(switch position II).
In order to put the unit back into operation,
switch back to the starting position (switch
position I).
Control unit switch
= unit
switched
on
= unit
switched
off
= light
switched
on
6 h
12 h