22
Installation Instructions - EmoTouch 3
Mounting
EN
4.2.2 Installing cabin lighting
Lighting can be installed anywhere, however not near rising hot air. The
light output in the relay box is set to inductive load by default, but light
bulbs, halogen HV bulbs and other resistive loads may also be connected
to it. If required, the light output can also be manually set to capacitive
loads.
Setting the light output, see 6.3 Defining the light source manually,
Cabin lighting is not included in the scope of delivery. Observe the sepa-
rate installation instructions for lighting.
Light source requirements:
Lighting must be dimmable
Minimal output 5 W
Resistive loads max. 100 W
Dimmable energy-saving bulbs max. 35 W
Light sources with conventional transformers max. 60 VA
Dimmable LED bulbs max. 60 W
NOTICE
Material damage
Lighting and the control panel could become damaged if non-
dimmable light sources are installed. In this case, the warranty be-
comes void.
Do not install the lighting in areas with rising hot air.
The lighting must conform to protection class IPX4 (splash-
proof) and be resistant to ambient temperatures.
Connect only dimmable light sources.
Control line connection: 5.2 Connections,
4.2.3 Fan
An exhaust fan can be mounted in the cabin and set via the control panel.
It must be possible to control the fan's speed using phase control.
The fan can be installed anywhere, however never near hot air that rises
from the heater.
The fan is not included in the scope of delivery. Observe the separate
installation instructions for the fan.