23
Waveform pattern
Amount of
waveform display
Auto measuring
Waveform store
Waveform/Readout
Page up/Page
down
Auto
Storage
Measuring/Waveform
Change
Period/Frequency
Stable waveform
display
5 groups of waveform
Voltage measuring Waveform:
1. Put the banana plug of the black P-wire into the cathode COM socket, and the red one to the anode V socket.
2. Spin the function switch to select a proper range (200mV~1000V) according to the magnitude of the measured signal.
3. Contact the test points with the test pen.
4. Press the “Waveform/Readout” key to display the present Voltage waveform.
Current measuring Waveform:
1. Put the banana plug of the black P-wire into the cathode COM socket, and the red one to the anode mA socket.
2. Spin the function switch to select a proper range (20mA~200mA) according to the magnitude of the measured signal.
3. Use the test pen series-connected to the circuit.
4. Press the “Waveform/Readout” key to display the present Current waveform.
5. Please refer to the Current measuring section for the connected pattern of the 10A Current waveform measuring.