![enware IFO SPIRA WC Installation And Maintenance Instructions Manual Download Page 7](http://html1.mh-extra.com/html/enware/ifo-spira-wc/ifo-spira-wc_installation-and-maintenance-instructions-manual_2416507007.webp)
www.enware.com.au
Call 1300 369 273
7
Water Inlet Connection
The water connection to the cistern inlet is a 1/2" BSP male,
bottom inlet.
Looking from the front of the pan, it is located on the right hand
side, on the bottom of cistern.
Install a cistern tap in the vicinity.
155
105
FRONT VIEW
Bottom
Inlet
1/2” BSP
Male
*
* See WC Set Out
650
355
340
415
470
355
460
900
Pan outlet
250
15
480
to top of seat (Pressalit IFO553/ 554 seat
)
Floor Mounting Method
Determine floor fixing requirements according to the quality and strength of the floor material,
and the site risk assessment.
If there are no support arms, or there is no possibility of using
support arms in future
, use:
• Silicone sealant fixing (Tiled or similar hard floor only. No Vinyl);
• Pan Screw fixing; or
• Bracket fixing (Optional - IFO98016 Bracket sold separately.)
If toilet has support arms or may have support arms in future
(raised height toilet models only), use:
• Pan Screw fixing; or
• Bracket fixing (Optional - IFO98016 Bracket sold separately.)
This installation information is a guide only. Appropriate fixing method must be determined by
site-specific risk assessment.