www.enware.com.au
Call 1300 369 273
15
SENSOR PROGRAM
Note: The sensor range may vary depending on the light-reflecting
characteristics of the object in the sensor range.
Switch
Switch
Sensing Range Distance
OFF
OFF
120mm approx. (Short)
ON
OFF
140mm approx. (Medium-Short)
OFF
ON
150mm approx. (Medium-Long)
ON
ON
180mm approx. (Long)
SENSOR RANGE
Switch
Switch
Switch
Switch
Function
OFF
OFF
OFF
OFF
15 sec Time Out, Wave-On Wave-Off
OFF
OFF
ON
OFF
30 sec Time Out, Wave-On Wave-Off
OFF
ON
OFF
OFF
45 sec Time Out, Wave-On Wave-Off
OFF
ON
ON
OFF
60 sec Time Out, Wave-On Wave-Off
SENSOR FUNCTIONS
Wave-On Wave-Off
Wave hand in front of sensor once to turn on,
Wave hand in front of sensor once to turn off.
Default time-out (maximum run time) setting from factory is 45 seconds for Wave-On Wave-Off (EMW802,
EMW803, ENM5072).
Switch
Switch
Switch
Switch
Function
ON
OFF
OFF
OFF
6 sec Flow Time, Time Flow
ON
OFF
ON
OFF
9 sec Flow Time, Time Flow
ON
ON
OFF
OFF
12 sec Flow Time, Time Flow
ON
ON
ON
OFF
15 sec Flow Time, Time Flow
Time Flow
Put hand in front of sensor to turn on, the water flows for the set period of time, then turns off
automatically.
Water flows for the set period of time regardless of any further hand movement.
Default time setting from factory is 6 seconds for Time Flow (EMW804, ENM5071).