User Manual
Gobi-640-17µm and Gobi-384-25µm-GigE, CL, CXP Camera
4. Electrical Interface
4.1. General Overview Connectors and Specifications
Connect all cables to the connectors at the camera back (see also
the connector and interface specifications overview of the Gobi-640-17µm and of the Gobi-
384-25µm.
Interface
Connector
Specification
Camera Protocol
Gobi-640-GigE and Gobi-384-GigE
Input power (12V DC)
Hirose HR10-7R-4SA(73)
12V ±10%
Trigger (either Trigger-
in or Trigger-out!)
SMA
Trigger in:
V
IN,L
= 0.8V Max.
V
IN,H
= 2V Min.
V
IN,MAX
= 30V
Internal Pull-down: R = 10k
Ω
Trigger out:
V
HIGH
= 3.3V ±10%
V
LOW
= 0V
Ethernet
RJ45 connector
GigE standard
GigE Vision
Gobi-640-CL and Gobi-384-CL
Input power (12V DC)
Hirose HR10-7R-4SA(73)
12V ±10%
Trigger (either Trigger-
in or Trigger-out!)
SMA
Trigger in:
V
IN,L
= 0.8V Max.
V
IN,H
= 2V Min.
V
IN,MAX
= 30V
Internal Pull-down: R = 10k
Ω
Trigger out:
V
HIGH
= 3.3V ±10%
V
LOW
= 0V
Mini-camera link
CONN SDR 26POS
VERT RECEPT
Serial control: 115200 baud, 8n1
Levels: RS-644
XSP Protocol
(see
Image acquisition: CL
CL Base protocol/
1 TAP for image
acquisition
Gobi-640-CXP
CoaXPress
BNC connector
CXP-1 (or CXP-2)
CXP
Trigger (either Trigger-
in or Trigger-out!)
SMA
Trigger in:
V
IN,L
= 0.8V Max.
V
IN,H
= 2V Min.
V
IN,MAX
= 30V
Internal Pull-down: R = 10k
Ω
Trigger out:
V
HIGH
= 3.3V ±10%
V
LOW
= 0V
Table 4-1 Electrical interface specs for Gobi-640/Gobi-384-GigE, CL, CXP interface
www.envision.co.kr
•Supporting your Vision
(주)앤비젼
서울시 금천구 가산동 550-1 IT캐슬 1동 603호 (153-768)
Tel.
02. 2624. 5503
Fax.
02. 2082. 6427
e-mail.